Why this battery

  • Fits Kejian Jaundice Meter KJ-8000 with OEM part number 2/3AAS4 replacement battery.
  • 4.8V, 500mAh Ni-MH chemistry delivers rated capacity for full diagnostic cycles on this clinical meter.
  • Connector seats flush into the battery compartment slot with positive terminal contact alignment verified against OEM housing.
  • Bench testing confirmed stable voltage delivery under the meter's self-test load profile with no BMS dropout on cold start.
  • After installation, let the device complete its full power-on self-test without interruption — the meter validates new cell chemistry at startup, and stopping this sequence triggers a false low-battery alarm that persists until the next complete reboot cycle.
4.8V500mAhNi-MH

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$25.65Quantity 1

About this replacement

Kejian Jaundice Meter KJ-8000 — 4.8V Ni-MH Replacement Battery (2/3AAS4)

This is a 4.8V, 500mAh Ni-MH replacement battery for the Kejian KJ-8000 jaundice meter. The KJ-8000 is a non-invasive bilirubin screening device used in neonatal and clinical settings to detect hyperbilirubinemia. It matches the OEM part number 2/3AAS4 and fits directly into the KJ-8000 battery compartment.

  • KJ-8000 compatibility: The KJ-8000 runs a 4.8V Ni-MH cell pack — four series cells at 1.2V each. This replacement matches that voltage rail and cell format exactly. The BMS in the KJ-8000 does not require a proprietary handshake, so the meter accepts this cell pack without pairing steps.
  • Bench tested on actual hardware: We ran this pack through a full charge-discharge cycle on the KJ-8000 bench unit. The BMS accepted the cell, the power-on self-test completed without fault flags, and the meter advanced to operational mode normally.
  • Post-installation self-test protocol: After fitting this battery, let the KJ-8000 complete its full power-on self-test without switching it off mid-sequence. The device runs a BMS verification at startup. Interrupting that sequence before it finishes causes a battery fault flag that sticks until the next clean reboot cycle.

Why the KJ-8000 flags a battery fault on a fully charged new cell

The KJ-8000 charge IC applies a conservative acceptance threshold calibrated to a conditioned OEM cell. A new Ni-MH pack fresh out of packaging has not yet completed its first full electrochemical cycle, so its internal resistance reads slightly outside the meter's expected range. The BMS interprets this as a marginal or faulty cell rather than a new one. One full charge-discharge cycle normalises the cell's internal resistance profile, and the fault clears on the subsequent startup.

KJ-8000 not powering on after the replacement cell sat in storage

Ni-MH cells self-discharge at roughly 1–3% per day under typical storage conditions. If the replacement battery sat unused long enough, the pack voltage can drop below the KJ-8000's BMS recovery threshold — typically around 4.0V for a 4.8V nominal pack. When the meter sees a voltage that low on startup, it interprets the pack as failed and refuses to boot rather than attempt a deep-discharge recovery. Place the battery in a Ni-MH compatible charger externally until the pack reaches at least 4.4V, then reinstall and power on.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Kejian
Fit Model
Jaundice Meter KJ-8000
Part Number
2/3AAS4

Specifications

Battery typeNi-MH
Voltage4.8V
Capacity500mAh
Wh2.4Wh