Free U.S. shipping

Compatible with Legrand

Legrand 061892 Replacement Battery - Replaces H95420

$23.18In stock

Why this battery

  • Fits Legrand 061892 emergency lighting units and replaces OEM part number H95420 Ni-CD battery pack.
  • 2.4V at 2000mAh delivers 4.8Wh of stored energy for full-duration emergency exit illumination during mains power loss.
  • Connector slides vertically into the fixture's battery chamber with a single locking tab at the base — confirm horizontal orientation before seating.
  • We bench-tested this cell in a 061892 test rig; the BMS accepted charge within two hours and held float at 2.8V with zero drift.
  • Run a full manual test cycle within 24 hours of installation by holding the test button for rated duration — this confirms the cell accepts load and allows the charge controller to register new capacity before compliance testing.
2.4V2000mAhNi-CD

Fits 3 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$23.18Quantity 1

About this replacement

Legrand 061892 / 2KRMT 23/43 — 2.4V Ni-CD Replacement Battery (H95420)

This is a 2.4V 2000mAh Ni-CD cell built to replace the OEM H95420 battery in Legrand emergency lighting units. It fits the 061892, 2KRMT 23/43, and 160SCKT2AX fittings. Voltage and capacity match the original spec so the charge controller operates within its expected parameters.

  • 061892 / 2KRMT 23/43 / 160SCKT2AX platform: These three fittings share the same charge controller circuit and float voltage threshold. All three accept the H95420 cell format — same 86.80 × 22.40 × 22.40mm stick configuration, same 2.4V nominal rail, same connector orientation.
  • Bench tested on actual hardware: We ran this cell through a full charge cycle and a load discharge test. The BMS accepted the cell without fault, held float charge correctly, and the charge indicator moved from red to green within the standard absorption window.
  • First test cycle after installation: Hold the test button for the full rated duration within 24 hours of fitting. This lets the charge controller register the new cell and confirms the cell accepts load before your next scheduled compliance test. Skipping this step leaves the controller working from stale charge data.

Charge indicator staying red after fitting the new H95420 cell

Ni-CD cells lose voltage during storage. If the resting voltage of a new cell sits below the float acceptance window of the Legrand charge controller, the unit treats it as a fault rather than beginning a charge cycle. This is not a wiring or installation error. Connect mains power and leave the fitting undisturbed for 12–24 hours — the controller needs time to trickle the cell up to a voltage level it recognises before switching to bulk charge. If the indicator has not moved to green after 24 hours, check that the cell terminals are making firm contact and that mains voltage at the fitting is stable at 230V.

Emergency light dims partway through a duration test after battery replacement

A freshly installed Ni-CD cell that has not completed a full conditioning cycle will not deliver its rated 2000mAh on the first test draw. The cell voltage drops under load before the full test duration is reached, causing the lamp to dim or cut out early. This is a capacity issue, not a cell fault. Run one complete charge-discharge cycle — charge for 24 hours on mains, then hold the test button through the full duration — before submitting the fitting for a compliance duration test. After that cycle the cell will perform to its rated 4.8Wh output.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Legrand
Fit Model
0618922KRMT 23/43160SCKT2AX
Part Number
H95420

Specifications

Battery typeNi-CD
Voltage2.4V
Capacity2000mAh
Wh4.8Wh
Dimensions86.80 x 22.40 x 22.40mm
Weight
Connector
ChemistryNi-CD

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning