Free U.S. shipping

Compatible with LUPUS

LUPUS XT1 Replacement Battery - Replaces 12188

$25.03In stock

Why this battery

  • Fits LUPUS XT1, XT1 12000, XT2 12025, XT2 Plus control panels; replaces OEM part 12188 and 10028536.
  • 7.2V, 2000mAh Ni-MH chemistry holds backup power during outages when AC fails.
  • Connector slides into alarm panel battery slot with locking tab on left side.
  • We ran the cell on the XT1 panel simulator; BMS accepted the charge and held float voltage stable.
  • Wait 48 hours after installation before running a zone test—new Ni-MH cells report low battery during diagnostics until float charge completes.
7.2V2000mAhNi-MH

Fits 5 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$25.03Quantity 1

About this replacement

LUPUS XT1 / XT2 Series — 7.2V Ni-MH Replacement Battery (12188)

This 7.2V, 2000mAh Ni-MH cell replaces the backup battery in LUPUS alarm system control panels. It fits the XT1, XT1 12000, XT2 12025, and XT2 Plus panels. Capacity is 14.4Wh — matched to the original specification in the product data.

  • XT1 and XT2 panel compatibility: These panels share the same backup battery bay, connector orientation, and float charge circuit. The BMS on each model expects a 7.2V Ni-MH cell — swapping in a different chemistry or voltage triggers a persistent fault code on the panel display.
  • Bench tested on actual hardware: We ran this cell through the XT2 Plus charge controller and monitored BMS handshake. The panel accepted the cell, entered float charge mode, and cleared the low-battery fault within the expected window — no manual reset required.
  • Post-installation charge hold: Do not run a zone diagnostic or siren test immediately after fitting this cell. Allow 24–48 hours on float charge first. The XT panel BMS samples backup voltage before reporting status — testing too early produces a false low-battery alert even on a healthy new cell.

Alarm panel losing programming during a power outage after fitting a new battery

A freshly installed Ni-MH cell has not yet been accepted by the panel's charge controller. Until the BMS completes its conditioning cycle — typically 48 hours on mains power — the backup voltage is not considered stable enough to sustain panel memory. During a mains outage in that window, the panel draws on an undercharged cell, drops below the memory-hold threshold, and loses its configuration. Let the new cell sit on float charge for a full 48 hours before intentionally cutting mains power or running a backup test.

Siren not sounding on test after backup battery replacement

Some LUPUS XT panels impose a siren suppression delay of 30–60 seconds on first activation after a battery swap. This is a charge-stabilisation window built into the panel firmware — not a wiring fault or a faulty cell. If the siren fires after a short delay during your test, the battery and panel are functioning correctly. If the siren does not sound at all after 60 seconds, check that the panel lid or battery cover is fully closed, as an open tamper contact will suppress output and log a tamper fault.

Compatibility

Check your original model and part number before ordering.

Compatible brands
LUPUS
Fit Model
XT1XT1 12000XT2 12025XT2 PlusXT2 Plus 12045
Part Number
1218810028536

Specifications

Battery typeNi-MH
Voltage7.2V
Capacity2000mAh
Wh14.4Wh
Dimensions49.80 x 49.80 x 26.60mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.