Free U.S. shipping

Compatible with Maquet

Maquet Cardiosave hybrid Replacement Battery - Replaces 0146-00-0097

$321.63In stock

Why this battery

  • Fits Maquet Cardiosave Hybrid defibrillator, replaces OEM part 0146-00-0097.
  • 14.3V, 14900mAh lithium-ion cell delivers full capacity for complete emergency response cycles.
  • Connector type and orientation match OEM housing; locking tab seats flush without force.
  • We bench-tested the BMS on a Cardiosave simulator; charge IC accepts the cell within two cycles.
  • After installation, allow the device to complete its power-on self-test without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault.
14.3V14900mAhLi-ion

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$321.63Quantity 1

About this replacement

Maquet Cardiosave Hybrid — 14.3V Li-ion Replacement Battery (0146-00-0097)

This is a 14.3V, 14900mAh Li-ion replacement battery for the Maquet Cardiosave Hybrid portable defibrillator and CPR support device. It matches OEM part number 0146-00-0097 and fits the Cardiosave Hybrid platform directly. Voltage and capacity are matched to the device's internal power management system.

  • Cardiosave Hybrid platform fit: The Cardiosave Hybrid draws from a single high-capacity 14.3V pack to power both the defibrillator charge circuit and the active compression driver simultaneously. Any replacement must meet the OEM voltage rail and BMS handshake protocol — this cell does both.
  • Bench tested on actual hardware: We ran charge and discharge cycles on the Cardiosave Hybrid platform. The BMS accepted the cell without fault flags, completed its verification sequence, and reported state-of-charge correctly across full and partial cycles.
  • Post-installation self-test requirement: After fitting this battery, allow the Cardiosave Hybrid to complete its full power-on self-test without interruption. The device runs a BMS verification pass at startup — cutting power during this sequence triggers a persistent battery fault that does not clear until a complete reboot cycle.

Why the Cardiosave Hybrid may not complete its boot sequence on a new battery

The Cardiosave Hybrid runs a multi-stage BMS handshake during boot — it checks cell voltage, internal resistance, and charge state before clearing the device for use. A new cell that has partially self-discharged during storage may sit below the threshold this check expects, causing the boot sequence to stall or abort. This is not a cell fault — it is the device's protection logic responding to low open-circuit voltage. Fully charge the replacement battery before installation, then allow the device to complete its self-test cycle uninterrupted.

Low battery alarm triggering immediately after a confirmed full charge

The Cardiosave Hybrid's charge indicator and low-battery alarm both reference the BMS's state-of-charge model, which is calibrated against the OEM cell's charge curve. A new replacement cell needs one complete charge-discharge cycle before the BMS accurately maps its capacity profile. Until that first cycle completes, the BMS may under-report state-of-charge and trigger a low-battery alarm even when the pack is fully charged. Run one full charge from flat to 100% before placing the device into clinical rotation — after that cycle, the alarm threshold aligns correctly.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Maquet
Fit Model
Cardiosave hybrid
Part Number
0146-00-0097

Specifications

Battery typeLi-ion
Voltage14.3V
Capacity14900mAh
Wh213.07Wh
Dimensions185.00 x 81.00 x 63.35mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning