Free U.S. shipping

Compatible with Medela

Medela Freestyle Breast Pump Replacement Battery - Replaces 919.7010

$29.97In stock

Why this battery

  • Fits Medela Freestyle Breast Pump, replaces OEM part number 919.7010.
  • 7.4V, 2600mAh lithium-ion cell delivers multiple pumping sessions per full charge cycle.
  • Connector slides into pump battery bay with positive contact alignment — locking tab seats flush when fully inserted.
  • We bench tested this cell on the Freestyle load profile; BMS initialized correctly and held voltage stable through discharge cycles.
  • After installation, let the pump complete its power-on self-test without interruption — medical devices verify BMS compatibility at startup, and stopping this cycle triggers a false battery fault that clears only on full reboot.
7.4V2600mAhLi-ion

Fits 1 model · Replaces 3 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$29.97Quantity 1

About this replacement

Medela Freestyle Breast Pump — 7.4V Li-ion Replacement Battery (919.7010)

This 7.4V, 2600mAh Li-ion battery replaces the internal rechargeable cell in the Medela Freestyle Breast Pump. It restores cordless operation to a pump that has lost charge capacity or stopped holding a charge altogether. OEM part numbers 919.7010, 67060, and 101034761 all reference this same cell configuration.

  • Freestyle Pump platform fit: The Freestyle uses a specific 7.4V two-cell Li-ion pack with a BMS that negotiates charge state with the pump's onboard charge IC. Voltage, connector pinout, and cell dimensions must all match — a generic Li-ion pack at the same voltage will not complete the handshake and the pump will flag a battery fault.
  • Bench tested on actual hardware: We cycled this pack through the Freestyle's charge IC and confirmed the BMS communicated correctly across charge and discharge. The pack accepted a full charge without triggering fault flags and held voltage within spec under the pump motor's draw profile.
  • Post-installation self-test: After fitting this battery, let the Freestyle complete its full power-on sequence without interruption. The pump runs a BMS verification check at startup. Interrupting it before the sequence finishes can log a false battery fault that stays active until the device is powered down and rebooted from scratch.

Why the Freestyle charge indicator stalls before reaching 100% on a new cell

The Freestyle's charge IC applies a conservative current limit when it detects a cell it has not previously profiled. On the first charge, the IC holds the termination voltage lower than normal and cuts off early — the indicator may stop at 85–90% and stay there. This is the charge controller being cautious, not a fault with the cell. Running one complete charge-to-discharge-to-charge cycle allows the IC to update its profile and the indicator will reach 100% on the second charge.

Freestyle powers on briefly then shuts off within seconds of starting a session

This happens when a replacement cell has been in storage long enough for self-discharge to pull it below the BMS recovery threshold — typically under 6.0V for a 7.4V two-cell pack. The pump draws enough current at motor start to trip the BMS undervoltage cutoff before the cell has had a chance to recover. Connect the pump to the charger and leave it for a minimum of 30 minutes before attempting to power on — the charge IC will trickle current into the cell until it clears the recovery threshold, after which normal charging resumes.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Medela
Fit Model
Freestyle Breast Pump
Part Number
919.701067060101034761

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity2600mAh
Wh19.24Wh
Dimensions70.00 x 40.10 x 21.00mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews