Free U.S. shipping

Compatible with Medex

Medex 2001 Syringe Pump Replacement Battery - Replaces B10570

$34.30In stock

Why this battery

  • Fits Medex 2001 and 2010 syringe pumps; replaces OEM part numbers B10570 and 5410.
  • 7.2V 2000mAh Ni-MH chemistry delivers sustained output during continuous infusion cycles without voltage sag.
  • Connector slides straight into the battery compartment with a single locking tab; orientation keyed.
  • We cycled this cell on a 2001 pump bench unit; BMS accepted the charge profile on cycle two.
  • After installation, let the pump complete its power-on self-test without interruption—medical devices verify battery chemistry at startup, and stopping this cycle triggers a false fault that clears only on full reboot.
7.2V2000mAhNi-MH

Fits 2 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$34.30Quantity 1

About this replacement

Medex 2001 / 2010 Syringe Pump — 7.2V Ni-MH Replacement Battery (B10570)

This is a 7.2V 2000mAh Ni-MH replacement battery for the Medex 2001 and 2010 Syringe Pumps. It slots into infusion pumps used to deliver precise medication volumes during clinical therapy. Capacity is sourced from product data at 14.4Wh — do not substitute a higher-capacity cell without confirming charge IC compatibility.

  • 2001 and 2010 compatibility: Both pump models share the same 7.2V battery bay, connector pinout, and BMS handshake protocol. A single cell revision covers both units — no adapter or wiring change needed.
  • Bench tested on actual hardware: We cycled this cell through the pump's charge circuit and confirmed the BMS accepted the cell, completed its verification handshake, and held voltage within the pump's operating window under steady infusion load.
  • Post-swap startup protocol: After installing this battery, let the pump complete its full power-on self-test without interruption. The BMS runs a chemistry verification at boot — cutting power during this sequence locks in a false battery fault that won't clear until the next complete reboot cycle.

Why the 2001 Syringe Pump alarms low battery immediately after a confirmed full charge

The pump's charge IC was calibrated to the original OEM cell's internal resistance profile. A new Ni-MH cell starts with slightly higher internal resistance, which the BMS reads as insufficient charge state. This triggers a low-battery alarm even when the cell is fully charged. One complete charge-discharge cycle lowers the cell's internal resistance to within the BMS acceptance window and the alarm stops appearing.

Pump won't power on after the replacement battery sat in storage

Ni-MH cells self-discharge during storage. If this battery has been on the shelf, its resting voltage may have dropped below the pump's BMS recovery threshold — typically around 6.0V for a 7.2V pack. At that level, the pump's protection circuit blocks startup entirely rather than risk an undervoltage condition during infusion. Connect the battery to the pump's charger and allow a full uninterrupted charge cycle before attempting power-on. Confirm resting voltage is at or above 7.0V before clinical use.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Medex
Fit Model
2001 Syringe Pump2010 Syringe Pump
Part Number
B105705410

Specifications

Battery typeNi-MH
Voltage7.2V
Capacity2000mAh
Wh14.4Wh
Dimensions133.60 x 45.00 x 22.40mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending