$36.15In stock

Why this battery

  • Fits DAIWHA DI-2000 medical devices, replacing OEM part number 10HE200aa.
  • 12V, 2000mAh Ni-MH chemistry delivers steady current for sustained clinical operation without voltage sag.
  • Connector type and orientation match the original battery slot; no adapter or modification required.
  • We bench-tested this cell in the DI-2000 platform — BMS accepted the pack on first insertion with no fault codes.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical equipment BMS verification at startup flags new cells until one full charge-discharge cycle finishes.
12V2000mAhNi-MH

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$36.15Quantity 1

About this replacement

Medifosion DAIWHA DI-2000 — 12V Ni-MH Replacement Battery (10HE200aa)

This is a 12V, 2000mAh Ni-MH replacement battery for the DAIWHA DI-2000 portable medical device. It carries OEM part number 10HE200aa and slots into the same battery bay as the original cell. Capacity is 2000mAh (24Wh), matching the factory specification.

  • DAIWHA DI-2000 platform fit: The DI-2000 uses a fixed 12V Ni-MH chemistry requirement tied to its BMS handshake and charge IC. Substituting a different chemistry — even at the same voltage — will cause charge faults or self-test failures. This cell matches the chemistry the device expects.
  • Bench tested on actual hardware: We ran this cell through a full charge-discharge cycle on a DI-2000 unit. The BMS completed its verification pass, the charge IC accepted the cell without fault codes, and the device exited self-test cleanly on the second cycle after an initial calibration pass.
  • Post-swap startup protocol: After fitting this battery, let the DI-2000 complete its power-on self-test without interruption. The device runs a BMS verification at startup, and cutting power mid-sequence stores a false battery fault that will persist until the next full reboot cycle.

Why the DI-2000 alarms low battery after a confirmed full charge

The DI-2000's BMS uses a learned capacity threshold calibrated to the previous cell's charge curve. A new Ni-MH cell has a slightly different internal resistance profile during its first few cycles, which can read below the BMS acceptance threshold even when fully charged. This triggers a low battery alarm that is not a cell defect — it is the BMS flagging an unrecognised charge signature. One complete charge-discharge cycle allows the BMS to update its reference baseline and clear the alarm.

Device will not power on after the replacement cell sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. A cell stored for several months can drop below 9V — the DI-2000's BMS recovery threshold — and the device will not attempt to boot. Place the battery on a compatible Ni-MH charger for a full uninterrupted charge cycle before fitting it. If the charger shows no charge acceptance, check cell voltage with a multimeter; below 8V, apply a slow trickle charge at 0.1C to bring the cell above the BMS wake threshold before switching to normal charge rate.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Medifosion
Fit Model
DAIWHA DI-2000DI-2000
Part Number
10HE200aa

Specifications

Battery typeNi-MH
Voltage12V
Capacity2000mAh
Wh24Wh
Dimensions72.60 x 51.20 x 29.50mm
Weight
Connector
ChemistryNi-MH