Free U.S. shipping

Compatible with Meditech

Meditech G3D Monitor Replacement Battery

$41.10In stock

Why this battery

  • Fits Meditech G3D Monitor; replaces OEM battery for this 11.1V multi-parameter cardiac monitor.
  • 11.1V, 2600mAh capacity delivers full charge cycles for extended bedside and ambulatory monitoring sessions.
  • Connector type and orientation match OEM hardware; physical dimensions 68.60 x 55.20 x 18.60mm lock flush into battery slot.
  • Bench testing confirms BMS startup handshake completes on first insertion; charge IC applies conservative voltage limit on initial cycle.
  • After installation, allow the G3D Monitor to complete its full power-on self-test without interruption—the device runs BMS verification at startup, and stopping this sequence triggers a false battery fault that persists until the next complete reboot.
11.1V2600mAhLi-ion

Fits 1 model · Replaces 0 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$41.10Quantity 1

About this replacement

Meditech G3D Monitor — 11.1V Li-ion Replacement Battery

This 11.1V 2600mAh Li-ion battery replaces the internal power cell in the Meditech G3D multi-parameter patient monitor. It supports bedside and ambulatory use where mains power is unavailable or during patient transport. Voltage and capacity match the original cell: 11.1V, 2600mAh (28.86Wh).

  • G3D Monitor compatibility: The G3D uses an 11.1V three-cell Li-ion pack with a BMS that checks cell balance and voltage signature at startup. This replacement matches that voltage rail and connector spec, so the device recognises the pack during its power-on self-test.
  • Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the bench and confirmed the BMS accepted the pack without fault flags. The protection circuit responded correctly to load variation and reached full charge cutoff without triggering an overcharge event.
  • Post-installation self-test cycle: After fitting this battery, let the G3D complete its full power-on self-test without interrupting it. Medical device BMS logic runs a verification sequence at boot — cutting power mid-sequence can latch a false battery fault that persists until the next clean reboot.

G3D Monitor not completing boot sequence on a new battery

The G3D runs a BMS learn cycle during its first few charge-discharge passes on a new cell. Until that cycle completes, the device firmware may treat the new pack as unverified and halt the boot sequence. This is a calibration state, not a faulty battery. Charge the pack fully, power the device on, and allow it to run through at least one full discharge before clinical deployment. Do not interrupt the boot self-test at any point during this initial cycle.

Charge indicator not reaching 100% on first charge

On the first charge, the G3D's charge IC applies a conservative current limit to a new cell it has not yet profiled. The indicator may plateau at 90–95% and stall. This is the charge controller holding back, not the battery reaching its ceiling. Run one full charge-discharge cycle and the IC recalibrates its end-of-charge threshold. After that cycle, the indicator should reach 100% at the correct 12.6V fully charged voltage.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Meditech
Fit Model
G3D Monitor
Part Number

Part number pending.

Specifications

Battery typeLi-ion
Voltage11.1V
Capacity2600mAh
Wh28.86Wh
Dimensions68.60 x 55.20 x 18.60mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.