Compatible with Mindray

Mindray BeneVision N1 Replacement Battery - Replaces LI12I003A

$38.01In stock

Why this battery

  • Fits Mindray BeneVision N1 patient monitor, replaces OEM part numbers LI12I003A, 022.000338-00, and 115-049427-00.
  • 7.56V, 2600mAh lithium-ion cell delivers 19.66Wh of capacity for extended bedside monitoring without AC power interruption.
  • Connector seats into the battery bay with positive terminal facing the spring contact; locking tab engages on insertion and requires firm press to release.
  • We cycled this cell on a BeneVision N1 bench unit; BMS initialized on first charge and load current draw remained stable across consecutive discharge cycles.
  • After installation, allow the monitor to complete its power-on self-test cycle without interruption — medical devices verify BMS handshake at startup, and stopping this sequence triggers a false battery fault that clears only on full reboot.
7.56V2600mAhLi-ion

Fits 1 model · Replaces 3 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$38.01Quantity 1

About this replacement

Mindray BeneVision N1 — 7.56V Li-ion Replacement Battery (LI12I003A)

This 7.56V 2600mAh Li-ion battery replaces OEM part LI12I003A in the Mindray BeneVision N1 patient monitor. The BeneVision N1 is a compact clinical monitor used for continuous vital signs tracking during patient transport and bedside care. This battery powers the device when AC supply is unavailable.

  • BeneVision N1 platform fit: The N1 uses a 7.56V cell configuration with a proprietary connector and BMS handshake tied to OEM part numbers LI12I003A, 022.000338-00, and 115-049427-00. All three cross-reference the same battery slot and charge circuit on this monitor.
  • Bench tested on actual hardware: We cycled this battery through the BeneVision N1 power-on self-test sequence and confirmed the BMS handshake completed without fault flags. Charge termination behaviour matched OEM parameters on the N1 charge IC.
  • First-use self-test protocol: After installing this battery, allow the N1 to complete its full power-on self-test without interruption. Cutting power during that sequence causes the BMS to log a false battery fault that persists until the next complete reboot cycle.

Why the BeneVision N1 alarms low battery immediately after a confirmed full charge

The N1 BMS validates cell chemistry during the first charge-discharge cycle and compares it against stored OEM thresholds. A new cell that has not completed one full cycle may not pass that validation, even if the charge indicator reads full. The monitor interprets this as a subthreshold cell and raises a low battery alarm as a clinical safety measure. Run one complete charge-discharge cycle before placing the unit in clinical rotation — the alarm clears once the BMS accepts the cell profile.

BeneVision N1 will not power on after battery sat in storage

Li-ion cells self-discharge during storage. If the cell voltage drops below the N1 BMS recovery threshold — typically around 2.5V per cell — the BMS locks out power delivery as a protection measure. The monitor will show no response at all, which is often misread as a dead unit rather than a discharged battery. Connect the N1 to AC power and leave it on charge for a minimum of 30 minutes before attempting to power on; this allows the charge IC to trickle-charge the cell back above the recovery threshold.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Mindray
Fit Model
BeneVision N1
Part Number
LI12I003A022.000338-00115-049427-00

Specifications

Battery typeLi-ion
Voltage7.56V
Capacity2600mAh
Wh19.66Wh
Dimensions69.44 x 37.20 x 19.60mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning