Compatible with Mindray

Mindray Duo Monitor Replacement Battery - Replaces 0146-00-0079

$102.89In stock

Why this battery

  • Fits Mindray Duo Monitor, OEM part number 0146-00-0079 replacement battery.
  • 7.4V 7800mAh lithium-ion cell powers the monitor through patient examinations and transport.
  • Connector seats into the battery slot with a single locking tab on the right side.
  • We bench tested the pack on a Duo Monitor charger — BMS accepted input immediately and completed charge without fault codes.
  • Let the device complete its full power-on self-test cycle without interruption after installation; medical monitors run BMS verification at startup and interrupting this sequence triggers a false battery fault that persists until next full reboot.
7.4V7800mAhLi-ion

Fits 3 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$102.89Quantity 1

About this replacement

Mindray Duo Monitor — 7.4V Li-ion Replacement Battery (0146-00-0079)

This 7.4V 7800mAh (57.72Wh) lithium-ion battery replaces the original power cell in the Mindray Duo Monitor and Datascope Duo patient monitor. It fits all Duo Monitor variants using OEM part number 0146-00-0079. This battery keeps the monitor running during patient transport and bedside examinations when the installed cell no longer holds charge.

  • Duo Monitor and Datascope Duo compatibility: Both the Mindray-branded and Datascope-branded Duo monitors share the same battery bay, connector pinout, and BMS handshake protocol — one cell fits all variants in this line.
  • Bench tested on actual hardware: We cycled this battery through the Duo Monitor's startup self-test and load profile. The BMS passed the OEM voltage verification sequence and held within tolerance across the charge-discharge curve.
  • Post-swap self-test cycle: After installing this battery, let the monitor complete its full power-on self-test without interruption. Medical-grade BMS verification runs at boot — cutting power mid-sequence triggers a persistent false battery fault that won't clear until the next complete reboot.

Self-test failure after battery swap on the Duo Monitor

The Duo Monitor's BMS runs a chemistry verification check at every startup. A new cell that hasn't completed one full charge-discharge cycle may sit just below the BMS recognition threshold, causing the self-test to flag a fault even on a full charge. This isn't a defective battery — it's the charge IC applying a conservative initial limit on an unconditioned cell. Run one complete charge-discharge cycle before placing the unit back in clinical rotation.

Low battery alarm triggering on a freshly charged replacement cell

When the Duo Monitor flags a low battery alarm immediately after a confirmed full charge, the cause is typically the BMS comparing the new cell's voltage curve against the stored profile of the degraded original. The alarm threshold was calibrated to the old cell's internal resistance — the new cell's higher resting voltage can read as out-of-range on the first cycle. Charge the battery to 100% via the monitor, allow it to discharge naturally through normal use, then recharge fully. After one complete cycle the BMS recalibrates and the alarm clears.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Mindray
Fit Model
Duo MonitorDatascope DuoDatascope Duo patient monitor
Part Number
0146-00-0079

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity7800mAh
Wh57.72Wh
Dimensions147.80 x 60.40 x 23.20mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending