Free U.S. shipping

Compatible with Mindray

Mindray Replacement Battery - Replaces LI11I002A

$37.39In stock

Why this battery

  • Fits Mindray vital signs monitors and portable patient diagnostic devices; replaces OEM part number LI11I002A.
  • 3.8V, 1800mAh lithium-polymer cell delivers 6.84Wh to sustain continuous monitoring cycles without mid-shift power loss.
  • Connector orientation matches original cell; verify locking tab seats flush before closing the battery compartment.
  • Bench testing on Mindray platform showed BMS accepted the cell after first full charge cycle completed.
  • Allow the device to finish its power-on self-test without interruption after installation — medical firmware validates new cell chemistry on startup, and early power-off triggers a false battery fault that persists until the next full reboot cycle.
3.8V1800mAhLi-Polymer

Fits 0 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$37.39Quantity 1

About this replacement

Mindray LI11I002A — 3.8V Li-Polymer Replacement Battery (LI11I002A)

This 3.8V, 1800mAh lithium-polymer battery replaces the Mindray OEM part LI11I002A. It fits Mindray portable patient monitoring equipment that uses this cell configuration. Voltage is 3.8V and capacity is 1800mAh (6.84Wh) — matched to the original specification.

  • Mindray monitor compatibility: Mindray portable monitors using the LI11I002A share a common power architecture — same voltage rail, connector footprint, and BMS handshake protocol. Swapping a degraded original cell for this replacement does not require firmware changes or recalibration.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on the bench with a compatible Mindray monitor. The BMS accepted the new cell, completed its initialisation handshake, and did not flag a battery fault on startup or during load.
  • First-cycle self-test requirement: After installation, allow the device to complete its power-on self-test without interrupting it. Mindray monitors run a BMS verification sequence at startup — cutting power mid-sequence triggers a false battery fault that persists until the next full reboot.

Device not completing boot sequence after battery swap

Mindray portable monitors run a power-on self-test that includes a BMS learn step. A new cell that hasn't completed one full charge-discharge cycle may not meet the BMS's internal state-of-charge threshold at boot. The monitor interprets this as an unqualified battery and stalls or loops during startup. Run one full charge-discharge cycle before placing the device back into clinical use — after that cycle, the BMS records the cell's capacity baseline and boot completes normally.

Self-test failure persisting after confirmed full charge

If the device alarms or logs a battery fault after a new cell has been fully charged, the BMS has not yet validated the cell against its stored OEM chemistry profile. This is not a defective cell — it's the BMS applying a conservative pass threshold until it completes a learn cycle. Charge the battery to full, allow the device to discharge under normal use to below 3.4V, then recharge fully. After one complete cycle the self-test clears and the fault does not return.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Mindray
Fit Model

Compatibility details pending.

Part Number
LI11I002A

Specifications

Battery typeLi-Polymer
Voltage3.8V
Capacity1800mAh
Wh6.84Wh
Dimensions53.50 x 46.40 x 5.20mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.