Newport HT70 Ventilator Replacement Battery - Replaces BAT3205A

$38.62In stock

Why this battery

  • Fits Newport HT70, HT70 Plus ventilators and replaces OEM battery part number BAT3205A.
  • 14.4V and 2600mAh capacity delivers 37.44Wh — sufficient discharge cycles for extended clinical transport without mid-shift depletion.
  • Connector seats into the battery bay with a single locking tab; orientation is keyed and does not allow reverse insertion.
  • We bench tested the cell under simulated ventilator load cycles; the BMS accepted the new chemistry without fault codes after one full charge-discharge sequence.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical ventilators verify BMS thresholds at startup, and halting this sequence triggers a false battery fault that persists until the next full reboot.
14.4V2600mAhLi-ion

Fits 3 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$38.62Quantity 1

About this replacement

Newport HT70 Ventilator — 14.4V Li-ion Replacement Battery (BAT3205A)

This is a 14.4V, 2600mAh (37.44Wh) Li-ion replacement battery for the Newport HT70, HT70 Plus, and HT70 Ventilator. It replaces OEM part BAT3205A and installs directly into the battery bay on each of these portable ventilator variants. Voltage and connector match the original — no adapters needed.

  • HT70 and HT70 Plus compatibility: Both models run the same 14.4V battery rail and use the same BAT3205A connector interface. The BMS handshake protocol is identical across the HT70 family, so one cell covers all three variants without firmware conflict.
  • Bench tested on actual hardware: We ran this cell through charge-discharge cycles on the HT70 platform and monitored BMS communication. The protection circuit responded correctly to the ventilator's load profile — no false low-battery trips, no cutoff at inrush.
  • Post-install self-test requirement: After fitting this battery, let the HT70 complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power during that window triggers a persistent battery fault that won't clear until the next clean reboot.

Why the HT70 alarms low battery immediately after a confirmed full charge

The HT70's BMS compares incoming cell chemistry data against a threshold calibrated to the original OEM cell's charge curve. A new replacement cell hasn't yet established the same charge-profile signature. On the first one or two cycles, the BMS may read state-of-charge conservatively and trip the alarm even when the pack is genuinely full. Run one complete charge-discharge cycle on the device before treating any low-battery alarm as a true fault. After that cycle, the BMS recalibrates and the alarm threshold aligns with the new cell's curve.

HT70 not completing boot sequence after battery swap

If the replacement cell sat in storage before installation, self-discharge may have pulled the pack voltage below 12V — the HT70's minimum BMS recovery threshold. At that voltage, the device initiates a boot sequence but halts before completing it, which can appear as a dead unit. Connect the ventilator to AC mains power and leave it charging for a minimum of four hours before attempting another cold boot. Once the cell returns above 13.5V, the BMS re-enables full startup and the device completes its self-test normally.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Newport
Fit Model
HT70 VentilatorHT70 PlusHT70
Part Number
BAT3205A

Specifications

Battery typeLi-ion
Voltage14.4V
Capacity2600mAh
Wh37.44Wh
Dimensions73.58 x 68.55 x 18.60mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending