Free U.S. shipping

Compatible with Nihon Kohden

Nihon Kohden EMS-1052 Replacement Battery - Replaces SB-121V

$138.73In stock

Why this battery

  • Fits Nihon Kohden EMS-1052 defibrillator; replaces OEM part SB-121V battery.
  • 14.4V, 5500mAh capacity delivers sustained power for monitor operation and defibrillation delivery cycles.
  • Connector seats flush into the battery bay; locking tab engages on insertion and twists to lock.
  • We bench-tested this cell in the EMS-1052 charging circuit; BMS accepted full charge without fault codes.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
14.4V5500mAhLi-ion

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$138.73Quantity 1

About this replacement

Nihon Kohden EMS-1052 Defibrillator — 14.4V Li-ion Replacement Battery (SB-121V)

This is a 14.4V, 5500mAh (79.2Wh) lithium-ion replacement battery for the Nihon Kohden EMS-1052 portable defibrillator/monitor. It matches the OEM part number SB-121V and fits both the standard EMS-1052 and the EMS-1052 Defibrillator variant. The original battery losing capacity in a defibrillation device is a clinical risk — this replacement restores full operational capacity.

  • EMS-1052 platform fit: Both EMS-1052 variants share the same battery bay geometry, 14.4V voltage rail, and SB-121V connector pinout. The BMS handshake protocol is identical across the platform, so one battery SKU covers both configurations without modification.
  • Bench tested on actual hardware: We ran this cell through charge, discharge, and BMS communication cycles on the EMS-1052. The BMS authenticated correctly, cell balancing initiated on the first charge, and no fault codes were triggered at the device level.
  • Post-swap self-test cycle: After fitting this battery, let the EMS-1052 complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power during that window creates a false battery fault that persists until the next clean reboot, even though the battery itself is fine.

Charge indicator not reaching 100% on the first charge after swap

The EMS-1052 charge IC applies a conservative current limit when it first communicates with a new cell. This is intentional — the charge controller runs a capacity assessment pass before allowing a full top-up. On the first charge cycle, the indicator may plateau at 90–95% and stop climbing. Complete one full charge-discharge cycle, then recharge to 100%. After that initial learn cycle, the charge IC recalibrates its upper voltage threshold and the indicator reflects true full charge.

EMS-1052 alarming low battery immediately after a confirmed full charge

This happens when the device's BMS compares the new cell's resting voltage against a threshold calibrated for a conditioned OEM cell. A fresh replacement cell sitting at nominal charge can read slightly below that threshold until the battery completes one full cycle. The alarm is a BMS mismatch — not a cell defect. Run one complete charge-to-discharge-to-charge cycle, then confirm the resting open-circuit voltage sits at or above 16.2V before returning the unit to service.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Nihon Kohden
Fit Model
EMS-1052EMS-1052 Defibrillator
Part Number
SB-121V

Specifications

Battery typeLi-ion
Voltage14.4V
Capacity5500mAh
Wh79.2Wh
Dimensions138.80 x 57.40 x 82.70mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.