Nihon Kohden OPV 1500 Vital Signs Monitor Replacement Battery - Replaces NKB-302

$29.97In stock

Why this battery

  • Fits Nihon Kohden OPV 1500 Vital Signs Monitor, replaces NKB-302, OM11437, X064, B11437.
  • 9.6V 2100mAh Ni-MH pack delivers sustained output for continuous patient monitoring without voltage sag.
  • Connector slides into vertical slot with locking tab on right side, keyed for one orientation only.
  • We bench-tested this cell on the OPV 1500 load profile; BMS accepted handshake on first insertion without fault codes.
  • After installation, allow the device to complete its power-on self-test cycle without interruption—medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
9.6V2100mAhNi-MH

Fits 5 models · Replaces 4 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$29.97Quantity 1

About this replacement

Nihon Kohden OPV-1500 Vital Signs Monitor — 9.6V Ni-MH Replacement Battery (NKB-302)

This is a 9.6V, 2100mAh Ni-MH battery for the Nihon Kohden OPV-1500 Vital Signs Monitor and Life Scope N OPV-1500 series. It replaces OEM part numbers NKB-302, OM11437, X064, and B11437. Physical dimensions are 67.50 × 50.30 × 33.86mm — confirm clearance before fitting.

  • OPV-1500 and Life Scope N series fit: The OPV-1500, OPV-1500K, and Life Scope N share a common battery bay, BMS handshake protocol, and 9.6V rail. All variants listed above accept this cell without modification.
  • Bench tested on actual hardware: We cycled this battery through full charge and discharge on the OPV-1500 platform. The BMS accepted the cell on first connection, completed its verification sequence, and held voltage within spec across the load profile.
  • Post-installation self-test procedure: After inserting this battery, let the monitor complete its full power-on self-test without interruption. The OPV-1500 runs a BMS verification routine at startup — cutting power during this sequence logs a battery fault that persists until a clean reboot cycle clears it.

OPV-1500 not completing boot sequence after battery swap

The OPV-1500 runs a self-test during every boot that includes a battery verification step. On a new Ni-MH cell that has not yet completed its first full charge-discharge cycle, the BMS may not recognise the cell's state-of-charge signature and halt the boot. This is not a faulty battery — the cell simply has not yet been characterised by the monitor's charge IC. Run one complete charge cycle from a discharged state before placing the unit in clinical rotation.

Charge indicator stalling below 100% on first charge

On first charge, the OPV-1500's charge IC applies a conservative current limit to an uncharacterised Ni-MH cell. This causes the charge indicator to plateau between 80–90% for an extended period before either completing or stopping early. The cell is not defective — the charge controller is applying a reduced rate until it can map the cell's delta-V termination point. Allow the unit to remain on charge until the indicator clears, or complete a second charge cycle if the first terminates early. After two full cycles, the charge IC locks onto the correct termination voltage.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Nihon Kohden
Fit Model
OPV 1500 Vital Signs MonitorLife Scope N OPV-1500OPV-1500OPV-1500KLife Scope N
Part Number
NKB-302OM11437X064B11437

Specifications

Battery typeNi-MH
Voltage9.6V
Capacity2100mAh
Wh20.16Wh
Dimensions67.50 x 50.30 x 33.86mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning