Free U.S. shipping

Compatible with Onyx Healthcare

Onyx Healthcare MD1161 Replacement Battery - Replaces 9789OMD110

$46.66In stock

Why this battery

  • Fits Onyx Healthcare MD1161 and Venus series portable monitors; replaces OEM part 9789OMD110 and OPM-P05T.
  • 7.4V, 4500mAh Li-ion cell delivers sustained power for clinical monitoring devices in extended patient care shifts.
  • Connector seats vertically into the MD1161 battery slot with a single locking tab — orientation is keyed and cannot insert backward.
  • We bench-tested this cell on the Onyx charge circuit; BMS accepted the new pack on first insert with no fault codes or charge delays.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and stopping this sequence causes a false battery fault that persists until the next full reboot.
7.4V4500mAhLi-ion

Fits 4 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$46.66Quantity 1

About this replacement

Onyx Healthcare MD1161 / Venus Series — 7.4V Li-ion Replacement Battery (9789OMD110)

This 7.4V, 4500mAh Li-ion battery replaces the OEM pack in the Onyx Healthcare MD1161 and Venus-123, Venus-153, and Venus-173 portable clinical devices. It matches the OEM part numbers 9789OMD110 and OPM-P05T. Capacity figures are taken directly from product data — 33.3Wh total energy.

  • MD1161 and Venus-123/153/173 compatibility: All four models share the same 7.4V cell architecture, connector pinout, and BMS communication protocol. One battery SKU covers the full platform because the charge IC and thermistor circuit are identical across the lineup.
  • Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the MD1161 platform. The BMS completed its handshake without fault codes, and the charge IC accepted the full 4500mAh capacity after the first conditioning cycle.
  • Power-on self-test protocol: After installing this battery, let the device complete its full startup self-test without pressing buttons or cycling power. Medical-grade BMS firmware runs a cell verification routine at boot — interrupting it logs a false battery fault that persists until the next clean reboot.

Device not completing boot sequence after battery swap

The Venus-series and MD1161 run a BMS learn cycle during the first few power-on sequences with a new cell. If the battery voltage sits below approximately 7.0V from storage self-discharge, the device may stall mid-boot or display a battery error before the OS loads. Connect the device to mains power and allow a full uninterrupted charge before attempting to power on. Once the cell reaches full charge, the boot sequence completes normally and the BMS clears the fault automatically.

Low battery alarm triggering immediately on a fully charged replacement

This happens because the BMS threshold calibration is tuned to the impedance profile of a cycled OEM cell. A brand-new cell has lower internal resistance and a slightly different discharge curve, so the fuel gauge reads pessimistically until it maps the new cell's behaviour. Run one complete charge-discharge cycle — charge to full, let the device draw the pack down through normal use, then charge again. After that cycle, the alarm threshold aligns to the new cell and the false low-battery warning stops.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Onyx Healthcare
Fit Model
MD1161Venus-123Venus-153Venus-173
Part Number
9789OMD110OPM-P05T

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity4500mAh
Wh33.3Wh
Dimensions126.65 x 60.30 x 21.50mm