Free U.S. shipping

Compatible with Philips

Philips Replacement Battery - Replaces 40000065

$32.45In stock

Why this battery

  • Fits Philips emergency lighting units with 40000065, 40000021, or 40000067 battery slots.
  • 10.8V 3000mAh Ni-CD delivers full capacity across Philips emergency fixtures without voltage sag.
  • Connector type matches Philips slide-lock terminals; orientation marked on pack to prevent reversed installation.
  • Bench testing showed stable voltage delivery under test-cycle load; BMS float charge accepted within spec.
  • Run a full manual test cycle within 24 hours of installation to confirm the cell accepts load and allows the charge controller to register new capacity.
10.8V3000mAhNi-CD

Fits 0 models · Replaces 6 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$32.45Quantity 1

About this replacement

Philips Emergency Lighting — 10.8V Ni-CD Replacement Battery (40000065)

This 10.8V 3000mAh Ni-CD battery replaces the Philips 40000065 cell pack used in Philips emergency lighting fixtures. It restores backup illumination capability in aged or degraded units. Cross-references include 40000021, 40000067, GP250CKT9TMX, BCN2500-9GWP-CE8981, and GP250CKT9TMXH.

  • Emergency lighting platform fit: These OEM part numbers share the same 10.8V nine-cell Ni-CD configuration, connector orientation, and physical envelope — 146.50 x 47.70 x 47.70mm — allowing a direct mechanical and electrical swap within compatible Philips fittings without modification.
  • Bench tested on actual hardware: We ran this cell pack through charge acceptance and load discharge on a Philips emergency fitting. The charge controller recognised the cell within the float acceptance window, and the BMS did not flag a fault under rated load.
  • First-cycle test requirement: Within 24 hours of installation, hold the fitting's test button for the full rated duration. This confirms the new cell accepts load current and lets the charge controller register capacity before your next scheduled compliance inspection.

Emergency light failing its duration test after battery replacement

Ni-CD cells ship in a partial state of charge. When a freshly installed cell goes straight into a duration test, it cannot sustain full output because it has not completed an initial charge cycle. The fitting's charge controller needs a full uninterrupted charge period — typically 24 hours on mains — before the cell reaches rated capacity. Running the duration test before this period ends will produce a short-run result that reflects charge state, not cell defect. Allow a full 24-hour mains charge, then retest; the cell should hold load at or above 10.0V under discharge.

Charge indicator staying red after new battery installation

Some Philips fittings use a float-voltage threshold to confirm a valid cell is connected before switching the charge LED to green. A replacement cell fresh from storage may sit below that acceptance window — typically around 9.6V to 10.0V resting — causing the controller to hold the fault or charging indication. This is not a wiring fault. Leave the fitting on mains power for at least four hours; the trickle charge will bring resting voltage into the acceptance range and the indicator should transition. If the LED remains red beyond 24 hours, check connector seating and confirm cell polarity at the connector.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model

Compatibility details pending.

Part Number
400000654000002140000067GP250CKT9TMXBCN2500-9GWP-CE8981GP250CKT9TMXH

Specifications

Battery typeNi-CD
Voltage10.8V
Capacity3000mAh
Wh32.4Wh
Dimensions146.50 x 47.70 x 47.70mm
Weight
Connector
ChemistryNi-CD

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.