Why this battery

  • Fits Philips E132, E132X, Xenium E132, Xenium E132x smartphones and replaces OEM part number AB1400DWMT.
  • Delivers 3.7V at 1300mAh capacity — sufficient for full-day messaging and call operation on standard use patterns.
  • Uses micro-connector with single locking tab; slides vertically into battery slot with gold contacts facing the phone's spring terminals.
  • Bench test showed normal BMS handshake on first insertion; fuel gauge IC initialized without lockout flags or voltage errors.
  • On first charge cycle after installation, disable fast charging in the phone settings — the fuel gauge needs one complete discharge-charge cycle to recalibrate against this cell's discharge curve before accepting high-current charging.
3.7V1300mAhLi-ion

Fits 4 models · Replaces 1 part number

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$23.18Quantity 1

About this replacement

Philips Xenium E132 / E132X — 3.7V Li-ion Replacement Battery (AB1400DWMT)

This is a 3.7V, 1300mAh Li-ion cell that replaces part number AB1400DWMT in the Philips E132, E132X, Xenium E132, and Xenium E132X. It fits directly into the battery bay and connects to the same three-contact strip the original uses. Capacity is 1300mAh — 4.81Wh — matching the factory specification.

  • E132 and E132X compatibility: Both variants share the same PCB layout, battery bay dimensions, and contact pinout. The BMS handshake runs on the same thermistor line, so the charge IC accepts this cell without flag errors on either model.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on the E132 platform. The BMS cleared charge-complete at 4.2V and set the low-voltage cutoff correctly. No thermal events at the charge IC during the first cycle on a fresh high-impedance cell.
  • First-cycle fuel gauge reset: After fitting this cell, disable fast charging and run one full discharge-to-charge cycle before resuming normal use. The fuel gauge IC on the E132 is calibrated to the old cell's discharge curve. One full cycle lets the coulomb counter recalibrate against the new cell before high-current charging is applied to an uncalibrated state.

Sudden shutdown at 20–30% on the Philips E132 after a cell swap

This is a voltage cliff issue, not a capacity defect. When the modem transmits or the screen runs at full brightness, current draw spikes sharply. A new cell with an uncalibrated fuel gauge IC can report 25% remaining while the actual terminal voltage drops below the BMS cutoff threshold under that load. The phone shuts off because the BMS correctly trips — it just doesn't know where the cliff is yet. One full discharge-charge cycle resets the coulomb counter and moves the reported percentage back in line with actual cell voltage.

Phone won't power on after the replacement battery sat in storage

Li-ion cells ship at a reduced state of charge — typically around 3.0V — to slow self-discharge during transit. If the cell drops below approximately 2.5V before installation, the BMS enters a lockout state and blocks normal charging to prevent damage. The phone shows nothing when you press the power button and may not respond to a charger at all. Connect the phone to a wall adapter — not USB from a PC — and leave it for 15–20 minutes without pressing anything; most Philips charge ICs apply a low trickle current that recovers the cell to a voltage where the BMS will re-initialise and allow a normal charge to begin.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
E132E132XXenium E132Xenium E132x
Part Number
AB1400DWMT

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity1300mAh
Wh4.81Wh
Dimensions
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.