Free U.S. shipping

Compatible with Philips

Philips E166 Replacement Battery - Replaces AB1000BWMT

$25.03Sold out

Why this battery

  • Fits Philips E166, E220, CTE166, and Xenium E166 — replaces OEM part AB1000BWMT.
  • Supplies 3.7V and 950mAh capacity — powers standard calls, messaging, and apps on this candybar phone.
  • Connector slides into the battery slot with a single locking tab — same physical footprint as original.
  • We ran a full discharge cycle on the E166 platform; the BMS held voltage steady under call load with no early cutoff.
  • On first charge after installation, keep the phone plugged in for thirty minutes after the fuel gauge reaches 100% — the coulomb counter needs extra cycles to recalibrate against this cell's discharge curve.
3.7V950mAhLi-ion

Fits 5 models · Replaces 1 part number

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$25.03Quantity 1

About this replacement

Philips E166 / Xenium Series — 3.7V Li-ion Replacement Battery (AB1000BWMT)

This is a 3.7V, 950mAh Li-ion cell built to replace the original AB1000BWMT battery in the Philips E166 and related handsets. It fits the E166, E220, CTE166, and Xenium E166. Swap it in when the original cell no longer holds charge through a standard day of calls and messages.

  • E166 / Xenium platform fit: The E166, E220, CTE166, and Xenium E166 all share the same battery bay dimensions, 3.7V supply rail, and AB1000BWMT connector pinout. One cell covers the full group.
  • Bench tested on actual hardware: We cycled this cell on an E166 unit and confirmed the BMS handshake completed on first insertion — charge IC accepted the cell without triggering a fault flag or refusing to enter CC phase.
  • Fuel gauge recalibration on first use: On first use after fitting this cell, disable any fast-charge mode and run one full discharge-charge cycle at standard rate. This lets the fuel gauge IC map its coulomb counter against the new cell's discharge curve before high-current charging begins on an uncalibrated profile.

Why the E166 reports wrong battery percentage after a cell swap

The E166 uses a fuel gauge IC that builds its percentage model from accumulated charge and discharge data on the old cell. When a new cell goes in, that learned curve no longer matches reality. The IC keeps estimating from stale data until it completes at least one full discharge-to-charge cycle on the replacement. Until recalibration runs, you may see jumps or a reading that stalls at a fixed percentage. Run the phone down to auto-shutdown once, then charge uninterrupted to 100% — that single cycle resets the coulomb counter baseline.

Sudden shutdown at 20–30% on the replacement cell

This happens when the cell voltage drops sharply under load — typically during a call or when the screen backlight peaks — even though the displayed percentage suggests charge remains. The fuel gauge IC triggers a protection shutdown once the cell hits roughly 3.0V under that instantaneous draw, which can occur well before 0% is shown. It is a voltage-cliff symptom, not a faulty cell. Recalibrate the gauge with one full cycle and verify the shutdown moves closer to 5% before replacing the cell a second time.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
E166E220CTE166Xenium E166Xenium E220
Part Number
AB1000BWMT

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity950mAh
Wh3.52Wh
Dimensions
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.