Why this battery

  • Fits Philips Ultrasound CX30, CX50, and EPIQ 5 systems; replaces OEM part numbers 453561446191, M6477, 453561446192, and 453561268715.
  • 14.8V and 6150mAh capacity delivers 91.02Wh of energy; matches the original chemistry and load profile for uninterrupted diagnostic imaging sessions.
  • Connector slides into the battery bay with a positive terminal contact and locking tab that seats flush against the device frame.
  • We bench-tested the BMS against the CX30 charger; the cell accepted charge linearly and reported voltage parity with OEM stock on full cycle.
  • After installation, allow the ultrasound to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and halting this sequence triggers a false battery fault that persists until the next full reboot.
14.8V6150mAhLi-ion

Fits 4 models · Replaces 5 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$214.11Quantity 1

About this replacement

Philips Ultrasound CX30 / CX50 / EPIQ 5 — 14.8V Li-ion Replacement Battery (453561446191)

This 14.8V 6150mAh (91.02Wh) Li-ion battery replaces the original power pack in the Philips CX30, CX50, Echographe CX50, and EPIQ 5 portable ultrasound systems. It matches the OEM voltage rail and connector configuration those platforms require. Compatible part numbers include M6477, 453561446192, and 453561268715.

  • CX30, CX50, and EPIQ 5 platform compatibility: These models share the same 14.8V four-cell battery architecture, BMS handshake protocol, and locking connector format. A single cell pack services all four variants without modification.
  • Bench tested on actual hardware: We cycled this battery through full charge and discharge on the CX30 platform. The BMS completed its authentication handshake, accepted charge from the internal charge IC, and held voltage above the 13.5V cutoff threshold under continuous imaging load.
  • Post-installation self-test cycle: After fitting this battery, let the ultrasound unit complete its full power-on self-test without interrupting or powering down mid-sequence. The CX30 and CX50 run a BMS verification routine at startup — cutting power during this sequence registers a battery fault that persists until the next clean reboot.

CX30 not completing boot sequence on a new battery

The CX30 runs a multi-stage self-test at startup that includes a BMS handshake and a minimum voltage check. A new cell that has partially self-discharged during storage may sit below the threshold the device expects at boot, causing the sequence to stall or abort. This is not a faulty battery — it is a state-of-charge issue. Connect the unit to mains power first, allow the battery to reach at least 80% charge, then attempt a cold boot.

Charge indicator stalls below 100% on first charge

On the first charge cycle, the CX50 and EPIQ 5 charge IC applies a conservative current limit to new cells it has not yet profiled. This is normal behaviour — the charge controller is running a capacity-learning pass, not reporting a fault. The indicator typically stalls between 85–95% for 20–40 minutes before completing. Run one full charge-to-discharge cycle before relying on the charge display for clinical scheduling.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
Echographe CX50EPIQ 5Ultrasound CX30Ultrasound CX50
Part Number
453561268715453561446191453561446192453561446197M6477

Specifications

Battery typeLi-ion
Voltage14.8V
Capacity6150mAh
Wh91.02Wh
Dimensions141.60 x 130.70 x 28.95mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning