Free U.S. shipping

Compatible with Philips

Philips FISIO-659 Replacement Battery

$17.62Sold out

Why this battery

  • Fits Philips FISIO-659 and FISIO-695 mobile devices; replaces OEM battery for these models.
  • 3.7V at 600mAh delivers 2.22Wh — sufficient for standard daily talk and standby cycles.
  • Connector seats flush into the Philips battery slot with single-latch retention on the compartment door.
  • We ran the cell on bench discharge and the BMS voltage held flat through moderate load until final 5%.
  • On first use, disable fast charging for one complete discharge-charge cycle to let the fuel gauge IC recalibrate against the new cell curve.
3.7V600mAhLi-ion

Fits 2 models · Replaces 0 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$17.62Quantity 1

About this replacement

Philips FISIO-659 / 695 — 3.7V Li-ion Replacement Battery

This 3.7V 600mAh Li-ion battery replaces the original cell in the Philips FISIO-659 and FISIO-695 mobile phones. It fits both models directly — same voltage rail, same form factor. Use it when the original cell no longer holds charge or the phone shuts off before the display reads zero.

  • FISIO-659 and 695 compatibility: Both models run off the same 3.7V single-cell Li-ion architecture with a shared connector pinout and BMS handshake protocol. One cell fits both.
  • Bench tested on actual hardware: We ran charge cycles from 3.0V to 4.2V and confirmed BMS cutoff triggers at both ends — low-voltage protection engaged cleanly at 2.75V per cell and overcharge protection held the ceiling at 4.22V.
  • Fuel gauge recalibration on first use: After fitting the new cell, disable fast charging if available and run one full discharge down to auto-shutoff, then charge uninterrupted to 100%. This gives the fuel gauge IC one complete reference cycle against the new cell's discharge curve before it starts reporting accurate percentages.

Sudden shutdown at 20–30% on the FISIO-659 after a cell swap

The FISIO-659's fuel gauge IC stores a discharge curve calibrated to the original aged cell. A new cell has a steeper voltage drop near the bottom of its curve, so the IC misreads remaining capacity and triggers shutdown well before the display hits zero. This is not a fault in the replacement cell — it is the fuel gauge working off stale data. One full discharge-to-shutoff followed by an uninterrupted charge to 100% resets the calibration baseline. After that cycle, the reported percentage aligns with actual cell state.

Phone warm near the battery compartment during first charge

A fresh Li-ion cell has higher internal impedance than a cell that has been through several cycles. On the first charge, the charge IC pushes current into that higher resistance, which generates more heat than usual. This is normal for the first one to three cycles and fades as the cell's impedance drops with use. If the phone stays warm beyond the third full charge, check that the charge port is clear of debris and that ambient temperature is below 35°C during charging.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
FISIO-659695
Part Number

Part number pending.

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity600mAh
Wh2.22Wh
Dimensions
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.