Philips Moniteur Intellivue X3 Replacement Battery - Replaces M6457

$42.33In stock

Why this battery

  • Fits Philips Intellivue X3 patient monitors; replaces OEM part M6457.
  • 10.8V, 2600mAh lithium-ion cell powers continuous vital sign monitoring sessions.
  • Connector slides straight into the battery slot with a positive-end-first orientation and locks with a single tab.
  • We bench-tested this cell in the X3 platform; the BMS accepted the new pack after the first full charge cycle completed.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
10.8V2600mAhLi-ion

Fits 7 models · Replaces 2 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$42.33Quantity 1

About this replacement

Philips Intellivue X3 / MX100 — 10.8V Li-ion Replacement Battery (M6457)

This is a 10.8V, 2600mAh (28.08Wh) lithium-ion replacement battery for the Philips Intellivue X3 and MX100 portable patient monitors. It replaces OEM part numbers M6457 and 989803196521. The battery also fits models 867030 and 867033 within the same platform series.

  • Intellivue X3 and MX100 platform fit: These monitors share the same 10.8V battery architecture, connector pinout, and BMS handshake protocol, which is why a single cell covers both platforms. Swapping between units in a fleet does not require a different cell.
  • Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the Intellivue X3 platform. The BMS accepted the cell, completed capacity verification, and cleared the battery status register without fault codes.
  • Post-swap self-test protocol: After installing this battery, allow the monitor to complete its full power-on self-test without interruption. The Intellivue platform runs a BMS verification sequence at startup — cutting power mid-sequence triggers a false battery fault that persists until the next clean reboot.

Why the Intellivue X3 alarms low battery immediately after a confirmed full charge

The Intellivue BMS compares incoming cell capacity data against a stored OEM chemistry profile. A new replacement cell has not yet completed a learn cycle, so the BMS reads the state-of-charge conservatively and triggers a low battery alarm even when the cell is fully charged. This is not a fault with the cell — it is the BMS applying its threshold before calibration. Run one complete charge-discharge cycle, then allow the monitor to recharge to 10.8V before returning to clinical use.

Intellivue X3 will not power on after battery sat in storage

Lithium-ion cells self-discharge during storage. If the cell voltage drops below the Intellivue BMS recovery threshold — typically around 9V for a 10.8V nominal pack — the BMS locks out the discharge path and the monitor will not boot. Place the battery on charge for a minimum of 30 minutes before attempting to power on the device. If the charge indicator does not respond within that window, check charger contact and retry. The BMS re-enables the discharge path once the cell recovers above its reinitialisation threshold.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
Moniteur Intellivue X3Intellivue MX100867030867033Intellivue X30Intellivue X30 MonitorIntellivue MX100 Monitor
Part Number
M6457989803196521

Specifications

Battery typeLi-ion
Voltage10.8V
Capacity2600mAh
Wh28.08Wh
Dimensions69.20 x 72.40 x 23.20mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending