Free U.S. shipping

Compatible with Philips

Philips Respirateur V60 Replacement Battery - Replaces 88881344

$81.88In stock

Why this battery

  • Fits Philips Respirateur V60, V60S, and Respironics V60, V60S models; replaces OEM part 88881344 and equivalent variants 107674, 1076374, M48385-B0, 1058272.
  • 14.4V 11000mAh lithium-ion pack delivers 158.4Wh to sustain full ventilator operation through extended patient care shifts without mid-cycle power loss.
  • Battery connector seats into the V60 dock with firm contact; locking tab engages fully and releases only under deliberate pressure to prevent accidental disconnection during transport.
  • We bench-tested this cell on Philips V60 charge dock with load simulation; BMS accepted the handshake on first cycle and held stable discharge curve through 80% depth without voltage sag.
  • After installation, allow the device to complete its full power-on self-test cycle without interruption — medical ventilators run BMS verification at startup, and stopping this sequence triggers a false battery fault that requires a complete device reboot to clear.
14.4V11000mAhLi-ion

Fits 4 models · Replaces 7 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$81.88Quantity 1

About this replacement

Philips Respirateur V60 / V60S — 14.4V Li-ion Replacement Battery (88881344)

This is a 14.4V, 11000mAh (158.4Wh) Li-ion battery for the Philips Respirateur V60 and V60S non-invasive ventilators. It also fits the Respironics V60 and V60S variants using the same battery bay and connector. Confirmed compatibility against OEM part numbers 88881344, 107674, 1076374, M48385-B0, 1058272, 989805626941, and 1056921.

  • V60 and V60S platform fit: Both the Respirateur and Respironics-branded V60 variants share the same 14.4V battery rail, physical connector, and BMS handshake protocol. One battery services the full platform without modification.
  • Bench tested on actual hardware: We cycled this battery on a V60 bench unit and monitored BMS communication throughout. The charge IC accepted the cell without fault codes, and the BMS reported state-of-charge accurately across the full discharge curve.
  • Power-on self-test cycle: After installing this battery, let the V60 complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power during this window causes a false battery fault that persists until the next clean reboot.

Why the V60 flags a battery fault after a successful charge

The V60 BMS sets internal acceptance thresholds calibrated to OEM cell chemistry and charge history. A new replacement cell has no stored cycle data, so the BMS treats it as an unknown source on first boot. This triggers a conditional fault flag even when the cell is fully charged. Running one complete charge-discharge cycle writes the baseline data the BMS needs to clear the flag and report status normally.

Charge indicator stalls below 100% on the first charge

On first charge, the V60 charge IC applies a conservative current limit to cells with no prior cycle history — this is expected behaviour, not a fault. The indicator stalls because the IC is holding a reduced topping rate until cell internal resistance settles. Disconnect, allow the battery to rest for 10 minutes, then reconnect and resume charging. After one full cycle, the charge IC recalibrates and the indicator reaches 100% normally.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
Respirateur V60Respirateur V60SRespironics V60Respironics V60S
Part Number
888813441076741076374M48385-B010582729898056269411056921

Specifications

Battery typeLi-ion
Voltage14.4V
Capacity11000mAh
Wh158.4Wh
Dimensions195.00 x 73.86 x 49.65mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.