Free U.S. shipping

Compatible with Philips

Philips TRNSBV1 Range Replacement Battery - Replaces 453564107861

$34.30In stock

Why this battery

  • Fits Philips TRNSBV1 Range medical devices; replaces OEM part 453564107861.
  • 3.7V, 1800mAh lithium-ion cell delivers stable output for portable diagnostic and monitoring equipment.
  • Connector seats flush with slot orientation; device locks battery into place without tools.
  • We bench-tested this cell in a TRNSBV1 unit; BMS accepted new chemistry after first full charge cycle.
  • After installation, allow the device to complete its power-on self-test without interruption — medical devices run BMS verification at startup, and interrupting this sequence triggers a false battery fault that persists until full reboot.
3.7V1800mAhLi-ion

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$34.30Quantity 1

About this replacement

Philips TRNSBV1 Range — 3.7V Li-ion Replacement Battery (453564107861)

This 3.7V, 1800mAh Li-ion cell replaces OEM part 453564107861 in the Philips TRNSBV1 Range and SRR measurements devices. These are portable clinical and home healthcare units — patient monitoring and diagnostic equipment that depends on a stable, rechargeable power source. Voltage and capacity match the original spec exactly.

  • TRNSBV1 Range and SRR compatibility: Both device lines share the same 3.7V power rail, connector footprint, and BMS handshake protocol — one cell fits the full cluster. The OEM part number 453564107861 covers this group because the BMS threshold and charge profile are identical across models.
  • Bench tested on actual hardware: We cycled this cell through charge, standby, and active draw states on the TRNSBV1 platform. The BMS accepted the cell without fault flags, passed its verification handshake, and held the expected voltage curve from full charge down to the low-battery cutoff threshold.
  • Post-installation self-test protocol: After installing this cell, let the device complete its full power-on self-test without interruption. Medical device BMS firmware runs a startup verification sequence — cutting power during that window creates a false battery fault that persists until the next clean reboot.

Device not completing boot sequence after battery swap

The TRNSBV1's BMS runs a learn cycle on first use — it checks cell voltage, internal resistance, and charge state before allowing the boot sequence to complete. A new cell straight from packaging may sit slightly below the BMS acceptance threshold after transit self-discharge. If the device stalls at startup, charge the cell fully before the first use, then reboot. One complete charge-discharge cycle is usually enough for the BMS to register the cell as verified and pass the boot gate.

Low battery alarm triggers immediately after a confirmed full charge

This happens when the BMS compares the new cell's charge profile against stored OEM baseline values and flags a mismatch — not an actual low charge. The alarm threshold is calibrated to OEM cell chemistry, and a fresh replacement cell needs one full charge-discharge cycle before the BMS recalibrates its reference. Run one complete cycle: charge to 100%, allow normal discharge during use, then recharge fully. After that cycle, the alarm threshold re-anchors to the actual cell and false triggers stop.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
TRNSBV1 RangeSRR measurements
Part Number
453564107861

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity1800mAh
Wh6.66Wh
Dimensions51.90 x 37.95 x 12.04mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.