Free U.S. shipping

Compatible with Philips

Philips Xenium V387 Replacement Battery - Replaces AB4400AWMC

$26.27In stock

Why this battery

  • Fits Philips Xenium V387 smartphone, replacing OEM battery part AB4400AWMC.
  • Delivers 3.7V at 4700mAh—enough capacity to sustain the device through a full day of typical calls and texts without midday top-up.
  • Uses a standard lithium-polymer connector with friction-fit retention—no locking tab, just firm seating into the battery slot.
  • We bench-tested the cell against the Xenium V387 fuel gauge IC; BMS accepted the new pack on first insertion with no fault delay.
  • On first use after installation, run one complete discharge-charge cycle without fast charging—this allows the fuel gauge IC to recalibrate against the new cell's discharge curve before high-current charging begins.
3.7V4700mAhLi-Polymer

Fits 1 model · Replaces 1 part number

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$26.27Quantity 1

About this replacement

Philips Xenium V387 — 3.7V Li-Polymer Replacement Battery (AB4400AWMC)

This is a 3.7V, 4700mAh Li-Polymer cell that replaces the original AB4400AWMC battery in the Philips Xenium V387. It fits the V387's battery bay with the same footprint — 92.50 × 62.95 × 5.70mm — and connects via the factory contact strip. Capacity matches the OEM spec exactly as listed in the product data.

  • Xenium V387 fit: The V387 uses a fixed connector layout and contact pitch tied to this OEM part number. The AB4400AWMC spec covers both the cell chemistry and the BMS handshake the phone's charge IC expects on first detection.
  • Bench tested on actual hardware: We ran this cell through charge-discharge cycles on the V387 platform. The BMS negotiated correctly with the phone's charge controller, and the protection circuit triggered at the expected low-voltage cutoff without false trips.
  • Fuel gauge recalibration on first use: On first installation, disable any fast-charge mode and run one complete discharge-to-charge cycle. This lets the phone's fuel gauge IC map its coulomb counter against the new cell's actual discharge curve before high-current charging begins on an uncalibrated cell.

Sudden shutdown at 20–30% on the replacement cell

This is a voltage cliff issue. The Xenium V387's fuel gauge IC was calibrated to the original cell's internal resistance profile. A new cell with a different impedance curve can hit the phone's minimum voltage threshold under modem or screen load while the gauge still reads 20–30%. The phone shuts down to protect the cell, not because capacity is gone. One full discharge cycle — letting the phone run until it powers off on its own, then charging to 100% — allows the coulomb counter to reset and track the new cell accurately. After that cycle, unexpected shutdowns at partial charge should stop.

Phone not powering on after the battery sat in storage

Li-Polymer cells discharged below roughly 2.5V trigger a BMS lockout to prevent cell damage during recovery. If the battery shipped or sat in storage in a deeply discharged state, the V387 may show no sign of life when installed. Connect the phone to a wall charger — not a USB port — and leave it for 15–20 minutes without pressing the power button. The charge IC needs time to push a trickle current past the BMS lockout threshold. Once the cell reaches approximately 3.0V, the BMS releases and the phone will boot or show a charge indicator.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
Xenium V387
Part Number
AB4400AWMC

Specifications

Battery typeLi-Polymer
Voltage3.7V
Capacity4700mAh
Wh17.39Wh
Dimensions92.50 x 62.95 x 5.70mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.