Free U.S. shipping

Compatible with Philips

Philips Xenium W8510 Replacement Battery - Replaces AB3300AWMC

$22.56In stock

Why this battery

  • Replaces AB3300AWMC battery in Philips Xenium W8510 candybar smartphone.
  • 3.8V, 3000mAh lithium-polymer cell delivers rated capacity after original battery degradation reduces usable charge.
  • Connector slides into the original slot with no locking tab — orientation marked on the pack.
  • We cycled the pack on a Philips charger; BMS accepted voltage handshake on first insertion without fault codes.
  • On first full charge after installation, complete one discharge-charge cycle before heavy phone use — the fuel gauge IC needs to recalibrate against this cell's discharge curve.
3.8V3000mAhLi-Polymer

Fits 2 models · Replaces 1 part number

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$22.56Quantity 1

About this replacement

Philips Xenium W8510 — 3.8V Li-Polymer Replacement Battery (AB3300AWMC)

This 3.8V, 3000mAh lithium-polymer cell replaces part number AB3300AWMC in the Philips Xenium W8510 candybar smartphone. It matches the original cell's dimensions (74.73 × 59.78 × 5.50 mm) and slots directly into the existing battery bay. Voltage and capacity align with OEM spec so the phone's charge IC operates within its expected input range.

  • Xenium W8510 fit: The W8510 uses a single-cell Li-Polymer pack with a 3.8V nominal rail. The AB3300AWMC connector and cell geometry are specific to this chassis — the BMS handshake expects a 3.8V nominal input, and a mismatched cell would push the charge IC outside its regulation window.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on the W8510 platform. The BMS accepted the cell without fault codes, held the charge curve through mid-cycle, and the protection circuit tripped correctly at the low-voltage cutoff threshold.
  • Fuel gauge recalibration on first use: On first use after installation, disable fast charging and run one complete discharge-to-charge cycle. This gives the fuel gauge IC time to map the new cell's actual discharge curve before the charge IC pushes high current into an uncalibrated cell — mismatched curves cause erratic percentage readings and premature cutoffs.

Sudden shutdown at 20–30% on the Xenium W8510

This is a voltage cliff symptom, not a capacity problem. When the modem transmits or the screen peaks brightness, instantaneous current draw spikes. An aged or freshly installed cell with an uncalibrated fuel gauge cannot sustain terminal voltage under that load, so the protection circuit reads a brown-out condition and cuts power. The OS percentage shown at shutdown is meaningless — it reflects the fuel gauge's stale coulomb count, not actual cell state. Run one full discharge cycle from 100% to automatic shutdown and recharge to 100% to let the coulomb counter re-anchor to the new cell.

OS showing wrong battery percentage after cell swap

The fuel gauge IC on the W8510 builds a discharge model calibrated to the original cell's internal resistance and voltage curve. A new cell has different impedance characteristics, so the IC's stored model produces inaccurate state-of-charge readings immediately after swap — you may see jumps of 10–20% or a percentage that stalls. One full uninterrupted discharge from 100% down to automatic shutdown, followed by a full charge, forces the coulomb counter to rewrite its reference curve against the new cell. After that cycle, percentage readings stabilise to within a few percent of actual charge state.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
Xenium W8510W8510
Part Number
AB3300AWMC

Specifications

Battery typeLi-Polymer
Voltage3.8V
Capacity3000mAh
Wh11.4Wh
Dimensions74.73 x 59.78 x 5.50 mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews