Free U.S. shipping

Compatible with Philips

Philips Xenium X596 Replacement Battery - Replaces AB4000DWMT

$23.79In stock

Why this battery

  • Fits Philips Xenium X596 and Xenium CTX596 smartphones, replacing OEM part AB4000DWMT or AB4000DWMV.
  • This 3.85V Li-Polymer cell delivers 3900mAh capacity — enough to restore a full day of dual-SIM standby and call time on the X596 hardware.
  • Connector seats into the battery slot with a single locking tab on the left side; the BMS contacts align flush when the cell slides in fully.
  • We cycled this cell through full charge and discharge on the X596 motherboard; the fuel gauge IC accepted the new BMS handshake without fault codes or early cutoff signals.
  • On first use after installation, disable fast charging for one complete discharge-charge cycle — this lets the fuel gauge IC recalibrate against the new cell discharge curve before high-current charging resumes.
3.85V3900mAhLi-Polymer

Fits 2 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$23.79Quantity 1

About this replacement

Philips Xenium X596 / CTX596 — 3.85V Li-Polymer Replacement Battery (AB4000DWMT)

This is a 3.85V, 3900mAh (15.02Wh) Li-Polymer cell for the Philips Xenium X596 and Xenium CTX596 dual-SIM smartphones. It replaces OEM part numbers AB4000DWMT and AB4000DWMV. Fit this when the original cell no longer holds a usable charge or the phone shuts down unexpectedly under load.

  • X596 and CTX596 shared platform: Both handsets run the same 3.85V battery rail and use identical connector geometry and BMS handshake logic — one cell covers both variants without modification.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on the X596 platform. The BMS accepted the full charge cycle without cutoff errors, and the protection circuit responded correctly to load spikes from the dual-SIM modem stack.
  • Fuel gauge recalibration on first use: On first use after installation, disable fast charging and run one complete discharge-charge cycle at standard rate. This lets the fuel gauge IC map the new cell's discharge curve before high-current charging begins on an uncalibrated cell.

Sudden shutdown at 20–30% on the Xenium X596

This is a voltage cliff failure. The cell voltage drops sharply under combined modem and display load before the percentage reading catches up. The phone's PMIC interprets the voltage drop as a critically low state and triggers an emergency shutdown — even though the OS still shows 20–30% remaining. It happens most often when both SIM slots are active simultaneously and the screen is on at full brightness. Run one full discharge cycle to let the coulomb counter re-anchor its zero-voltage reference point against the new cell.

Phone won't power on after sitting in storage with a flat battery

Li-Polymer cells that drop below approximately 2.5V trigger a BMS protection lockout — the circuit opens to prevent damage and the phone will not respond to a normal charge connection. Plug in via USB and leave for 15–20 minutes without attempting to power on; the charge IC trickle-charges the cell back above the lockout threshold at a low current rate. Once voltage recovers to around 3.0V, the BMS re-initialises and the phone should respond normally. If the cell remains unresponsive after 30 minutes on charge, the cell has likely suffered irreversible over-discharge.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Philips
Fit Model
Xenium X596Xenium CTX596
Part Number
AB4000DWMTAB4000DWMV

Specifications

Battery typeLi-Polymer
Voltage3.85V
Capacity3900mAh
Wh15.02Wh
Dimensions84.10 x 65.35 x 4.06mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.