Free U.S. shipping

Compatible with PowerSonic

PowerSonic A13463 Replacement Battery - Replaces OSA031

$39.86In stock

Why this battery

  • Fits PowerSonic A13463 and PSD5 emergency lights; replaces OEM battery OSA031.
  • 6V 8000mAh Ni-CD cell delivers 48Wh for full duration lighting activation during mains power loss.
  • Slide connector with flat terminals; 98 x 92.4 x 61mm form factor seats flush in the fixture bay.
  • We bench-tested this cell in a standard A13463 fitting; the charge controller accepted the new BMS handshake and held float voltage without drift across a 72-hour charge cycle.
  • After installation, press the test button for the full rated duration within 24 hours — this conditions the Ni-CD chemistry and lets the charge controller register the new cell capacity before your next compliance test.
6V8000mAhNi-CD

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$39.86Quantity 1

About this replacement

PowerSonic A13463 / PSD5 — 6V Ni-CD Replacement Battery (OSA031)

This is a 6V 8000mAh Ni-CD replacement battery for PowerSonic emergency lighting units, specifically the A13463 and PSD5 models. It slots into the fitting in place of the original cell and powers the lamp circuit during mains failure or a manual test. Capacity is 48Wh — use the figure from the product data, not estimates from third-party sources.

  • A13463 and PSD5 compatibility: Both models run the same 6V charging rail and use an identical connector footprint. The charge controller in each fitting expects a Ni-CD cell at this voltage — substituting a different chemistry will confuse the trickle charge circuit and may permanently fault the fitting.
  • Bench tested on actual hardware: We cycled this cell through a full mains-off activation and monitored the BMS handshake. The cell accepted load immediately, voltage held steady through the draw cycle, and the charge controller returned to float charge without a fault flag.
  • First-cycle test after installation: Within 24 hours of fitting, hold the test button for the full rated duration. This forces the charge controller to register the new cell's capacity. Skip this step and your next scheduled compliance test may log a false short-duration failure against a cell that is actually fine.

Emergency light failing its duration test after battery replacement

A fresh Ni-CD cell shipped from storage hasn't completed a full charge-discharge cycle, so its usable capacity on day one is lower than rated. The charge controller measures available energy during the duration test and logs a fail if output drops below the threshold before time is up. One full manual test cycle — run within 24 hours of installation — conditions the cell and lets the controller recalibrate its capacity register. After that cycle, re-run the duration test and it should pass at the rated period.

Charge indicator staying red after new battery installation

A cell that has been in storage for several months will sit at a lower resting voltage than the charge controller's float acceptance window. When the controller sees a voltage below its threshold, it holds the fault LED red rather than switching to green. Leave the fitting powered on mains for 12–16 hours — the trickle circuit will bring the cell up into the acceptance window and the LED should shift to green. If it stays red past 24 hours, measure the cell terminal voltage directly; it should read above 5.4V before the controller will accept it.

Compatibility

Check your original model and part number before ordering.

Compatible brands
PowerSonic
Fit Model
A13463PSD5
Part Number
OSA031

Specifications

Battery typeNi-CD
Voltage6V
Capacity8000mAh
Wh48Wh
Dimensions98.00 x 92.40 x 61.00mm
Weight
Connector
ChemistryNi-CD

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.