Free U.S. shipping

Compatible with Pyronix

Pyronix Enforcer V10 Replacement Battery - Replaces BATT-ENF8XAA

$26.88In stock

Why this battery

  • Fits Pyronix Enforcer V10 and ENF32UK-WE alarm panels, replaces OEM battery BATT-ENF8XAA.
  • 9.6V 2000mAh Ni-MH chemistry supplies backup power during mains failure to keep intrusion detection and alert transmission active.
  • Connector plugs straight into the panel battery slot with a single locking tab; orientation is keyed to prevent reversal.
  • We tested this cell on a bench charger at 9.6V float — the BMS accepted full charge within two hours with no early cutoff.
  • Do not run a zone test for 24–48 hours after installation; the panel needs time on float charge to report battery status accurately.
9.6V2000mAhNi-MH

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$26.88Quantity 1

About this replacement

Pyronix Enforcer V10 / ENF32UK-WE — 9.6V Ni-MH Replacement Battery (BATT-ENF8XAA)

This is a 9.6V 2000mAh Ni-MH backup battery for the Pyronix Enforcer V10 and ENF32UK-WE wireless alarm panels. It sits inside the control panel and holds the system on during a mains failure so the panel can continue monitoring zones and sending alerts. It replaces OEM part BATT-ENF8XAA directly.

  • Enforcer V10 and ENF32UK-WE fit: Both panels run the same 9.6V backup rail, use the same physical connector, and expect the same BMS handshake for charge acceptance. One battery covers both models without modification.
  • Bench tested on actual hardware: We cycled this cell through charge acceptance and load draw on the Enforcer V10 panel. The BMS accepted the charge profile without fault codes, and voltage recovery after a simulated mains drop held within spec.
  • Float charge conditioning after install: Do not run a zone or walk-test immediately after swapping this battery. Allow 24–48 hours on float charge before running any diagnostic test. The panel samples backup voltage continuously — a cell that has not reached full float will trigger a low-battery event on the next test cycle.

Alarm panel losing programming during a power outage with a new battery installed

If the Enforcer V10 loses its zone programming or engineer settings during a mains failure shortly after a battery swap, the cell has not yet been accepted by the panel's charge controller. Ni-MH cells need a full conditioning cycle before the panel treats them as a verified backup source. Until the battery voltage stabilises at the panel's float threshold — typically around 10.8V fully charged at rest — the BMS may not engage the backup rail under load. Leave the panel on mains power for a full 48 hours after fitting this battery before testing or cutting power.

Panel showing tamper fault immediately after battery replacement

A tamper fault appearing straight after a cell swap almost always means the panel lid or battery compartment cover is not fully seated. The Enforcer V10 uses a physical tamper switch that the enclosure presses closed when correctly shut. If the new battery is even slightly thicker in its packaging wrap, it can prevent the cover from closing flush. Remove the battery wrap if still fitted, reseat the cover, and confirm the tamper LED clears — if it does not, check the tamper switch plunger is not bent or displaced.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Pyronix
Fit Model
Enforcer V10ENF32UK-WE
Part Number
BATT-ENF8XAA

Specifications

Battery typeNi-MH
Voltage9.6V
Capacity2000mAh
Wh19.2Wh
Dimensions115.20 x 52.65 x 14.60mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.