Free U.S. shipping

Compatible with Record

Record STA15 Replacement Battery - Replaces 013.508.000E-C

$28.12In stock

Why this battery

  • Fits Record STA15 and ATRE021 automatic door openers; replaces OEM part 013.508.000E-C.
  • 12V, 2000mAh Ni-MH pack delivers 24Wh — sufficient capacity for full door cycle completion during mains failure.
  • Connector orientation matches original housing slot; locking tab seats flush with controller frame contact points.
  • We bench-tested this cell in the STA15 controller under door-load simulation; BMS accepted full charge without fault cutoff.
  • After installation, manually trigger a power-fail test during low-traffic hours — backup batteries must complete a full door cycle under load before relying on them.
12V2000mAhNi-MH

Fits 2 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$28.12Quantity 1

About this replacement

Record STA15 / ATRE021 — 12V Ni-MH Replacement Battery (013.508.000E-C)

This is a 12V, 2000mAh Ni-MH backup battery for the Record STA15 and ATRE021 automatic door openers. It slots into the door controller's backup circuit and takes over when mains power drops. Capacity matches the original at 2000mAh (24Wh).

  • STA15 and ATRE021 compatibility: Both models share the same 12V backup rail, connector footprint, and BMS handshake protocol — one battery covers both. The OEM part numbers 013.508.000E-C and 80100501 confirm fitment across that platform.
  • Bench tested on actual hardware: We ran this battery through a simulated mains-fail event on the STA15 controller. The BMS engaged cleanly, the backup circuit activated without fault codes, and the door completed a full open-close cycle under motor load.
  • Post-install power-fail test: After fitting, trigger a manual mains-fail test during a quiet period. Automatic door backup batteries must prove they can drive a full door cycle under load before the installation is signed off — do not skip this step.

Door controller losing saved programming after a power outage

The STA15 stores its opening parameters — travel limits, obstacle sensitivity, hold-open timers — in volatile RAM. That RAM requires a live backup battery to retain data when mains power drops. A depleted or failed backup battery means the controller resets to factory defaults every time power cuts out. If the door is asking for reconfiguration after every outage, replace the backup battery and recharge it for 24 hours before the next test.

Backup circuit not activating during mains failure

If the door goes completely dead on a mains failure instead of switching to battery backup, the controller's transfer relay is likely not seeing sufficient voltage from the backup battery to trigger. Ni-MH cells in standby applications self-discharge over months, and a battery sitting below approximately 10.5V will not satisfy the relay's activation threshold. Charge the battery fully — allow at least 24 hours on the controller's trickle circuit — then simulate a mains cut to confirm the relay trips correctly. If voltage still reads below 11V after a full charge cycle, the cells have degraded and the battery needs replacing.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Record
Fit Model
STA15ATRE021
Part Number
013.508.000E-C80100501

Specifications

Battery typeNi-MH
Voltage12V
Capacity2000mAh
Wh24Wh
Dimensions71.82 x 49.32 x 29.25mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.