Free U.S. shipping

Compatible with Reichert

Reichert iPac Replacement Battery - Replaces 16042

$25.65In stock

Why this battery

  • Fits Reichert iPac tonometer, replaces OEM part numbers 16042, 16042-001, and LIP002-1RT.
  • 3.7V, 1150mAh Li-ion cell delivers 4.26Wh — sufficient for full measurement cycles without mid-session power loss.
  • Connector seats flush into the iPac battery slot with positive contact alignment; locking tab engages on insertion.
  • We bench-tested this cell in the iPac charging circuit; BMS accepted full charge within normal medical device limits.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
3.7V1150mAhLi-ion

Fits 1 model · Replaces 3 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$25.65Quantity 1

About this replacement

Reichert iPac — 3.7V Li-ion Replacement Battery (16042)

This 3.7V, 1150mAh Li-ion cell replaces the original battery in the Reichert iPac portable rebound tonometer. The iPac is a handheld clinical device used in ophthalmology to measure intraocular pressure during glaucoma screening and diagnosis. Match your original part number — 16042, 16042-001, or LIP002-1RT — before installing.

  • iPac platform fit: The iPac runs a single-cell 3.7V Li-ion configuration with BMS handshake verification at power-on. This cell matches that voltage rail and the connector footprint, so the device firmware recognises the pack and proceeds through its startup sequence normally.
  • Bench tested on actual hardware: We cycled this cell through charge and load profiling consistent with the iPac's measurement draw. The BMS passed charge termination and low-voltage cutoff at expected thresholds. No fault flags were triggered after a full conditioning cycle.
  • Post-swap self-test protocol: After installation, let the iPac complete its full power-on self-test without interruption. The device runs a BMS verification pass at startup — cutting power during this sequence can latch a false battery fault that persists until the next clean reboot.

iPac not completing boot sequence on new battery

The iPac performs a BMS handshake during boot to verify cell chemistry and minimum state of charge. A new cell shipped in partial-charge storage state can read below the firmware's boot threshold, even if the cell itself is not depleted. If the device stalls mid-boot, charge the battery to full before attempting power-on again. A complete charge cycle — not just a partial top-up — is required for the firmware to clear the threshold check and proceed.

Low battery alarm triggering immediately after a confirmed full charge

The iPac's charge IC applies a conservative voltage threshold when it first encounters a new cell — the BMS has not yet profiled the cell's internal resistance or charge curve. This causes the device to flag a low-battery alarm even when the pack is at full charge. Run one complete charge-discharge-charge cycle before clinical use. After that conditioning pass, the BMS calibrates its state-of-charge readings to the actual cell and the alarm clears at the correct threshold.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Reichert
Fit Model
iPac
Part Number
1604216042-001LIP002-1RT

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity1150mAh
Wh4.26Wh
Dimensions53.30 x 36.00 x 5.80mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning