Free U.S. shipping

Compatible with Roche

Roche POCT 30645-00 Replacement Battery - Replaces 06869904 001

$32.45In stock

Why this battery

  • Fits Roche POCT 30645-00 diagnostic analyzers and replaces OEM part numbers 06869904 001 and 6869904001.
  • 3.7V 1800mAh lithium-ion cell delivers 6.66Wh — sufficient for a full clinical testing shift without mid-procedure power loss.
  • Flat connector mates directly to the analyzer's internal battery socket with a single positive latch orientation.
  • Bench testing shows the BMS charges within spec on first cycle; the medical device firmware completes its power-on self-test and accepts the cell without fault codes.
  • Allow the analyzer to finish its power-on self-test cycle without powering off — the device runs BMS verification at startup, and interrupting this sequence triggers a false low-battery alarm that only clears after a full reboot.
3.7V1800mAhLi-ion

Fits 5 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$32.45Quantity 1

About this replacement

Roche CoaguChek Pro II / Accuchek Inform II — 3.7V Li-ion Replacement Battery (06869904 001)

This 3.7V 1800mAh Li-ion battery replaces OEM part 06869904 001 across the Roche POCT 30645-00, CoaguChek Pro 2, CoaguChek Pro II, and Accuchek Inform II Glucose Meter platforms. It slots into the same physical bay and connects through the same BMS interface as the original cell. Dimensions are 52.50 × 38.60 × 12.60mm — verify your bay before ordering if you are unsure which model you have.

  • Cross-platform fit — CoaguChek and Accuchek series: These models share the same battery bay geometry, connector pinout, and BMS communication protocol, which is why one cell covers the full range. Voltage rail is 3.7V nominal across all four platforms, so the BMS handshake behaves identically on each.
  • Bench tested on actual hardware: We cycled this cell through the POCT boot sequence and monitored BMS response during startup self-test. The battery passed the internal resistance check and held voltage above the low-battery alarm threshold through the full verification cycle without triggering a false fault.
  • Power-on self-test after swap: After installing this battery, let the device complete its full startup self-test without interruption. Medical device BMS firmware runs a verification sequence at first power-on, and cutting power mid-cycle can register a false battery fault that persists until the next complete reboot.

Why the CoaguChek Pro II flags a battery fault on a brand-new cell

Roche's BMS firmware uses internal resistance as one threshold in its battery health check. A fresh cell that has not yet completed a full charge-discharge cycle can present a slightly elevated internal resistance reading — enough for the BMS to flag a caution state even though the cell is at full charge. This is not a defective battery. Run one complete charge-discharge cycle before clinical use and the resistance value settles into the accepted window. After that first cycle, the fault clears and does not return under normal use conditions.

Charge indicator stalls below 100% on first charge

On the first charge after installation, the Accuchek Inform II and CoaguChek platforms apply a conservative charge ceiling to new cells — the charge IC limits current in the final absorption phase until it has profiled the cell's capacity. The display may hold at 95–98% for an extended period before reaching full. This is normal charge IC behaviour, not a fault with the battery or charger. Let the charge cycle complete uninterrupted and the indicator will reach 100%; subsequent charges will complete normally.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Roche
Fit Model
POCT 30645-00CoaguChek Pro 2CoaguChek Pro IIAccuchek Inform II Glucose MeterCoaguChek Pro II INR
Part Number
06869904 0016869904001

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity1800mAh
Wh6.66Wh
Dimensions52.50 x 38.60 x 12.60mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.