Free U.S. shipping

Compatible with SCHWA

SCHWA ECO+ EMP4 Replacement Battery - Replaces 101041

$28.74In stock

Why this battery

  • Fits SCHWA ECO+ EMP4 medical device, replaces OEM part number 101041.
  • 4.8V, 2000mAh Ni-MH chemistry delivers consistent power for portable medical monitoring and diagnostic applications.
  • Connector and orientation match OEM pack; slot geometry confirmed on hardware without modification.
  • We bench-tested this cell on the EMP4 platform — BMS accepted the pack after one full charge-discharge cycle without fault codes.
  • After installation, allow the device to complete its power-on self-test cycle without interruption; medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
4.8V2000mAhNi-MH

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$28.74Quantity 1

About this replacement

SCHWA ECO+ EMP4 — 4.8V Ni-MH Replacement Battery (101041)

This is a 4.8V, 2000mAh Ni-MH replacement battery for the SCHWA ECO+ EMP4 portable medical device. It matches OEM part number 101041 and fits directly into the EMP4 housing without modification. Voltage and capacity are matched to the original cell specification.

  • ECO+ EMP4 platform fit: The EMP4 runs a 4.8V Ni-MH cell stack with a BMS that verifies cell chemistry and voltage signature at startup. This replacement meets that voltage rail and chemistry requirement so the device completes its power-on verification without throwing a battery fault.
  • Bench tested on actual hardware: We ran this cell through the EMP4 charge cycle and monitored BMS handshake at power-on. The charge IC accepted the cell without error, and the self-test cleared on the first complete charge-discharge pass.
  • Post-installation self-test protocol: After fitting this battery, allow the EMP4 to complete its full power-on self-test cycle without interruption. The BMS runs a chemistry verification sequence at startup — cutting power mid-sequence logs a false battery fault that persists until the next clean reboot cycle.

Device not completing boot sequence on new battery

The EMP4 BMS checks cell voltage against a minimum threshold before allowing the boot sequence to proceed. A new Ni-MH cell that has been in storage can self-discharge below that threshold — typically under 4.4V — and the device interprets this as a depleted or failed cell. The fix is to place the battery on charge before first installation and allow it to reach a full charge state. Once voltage recovers above the BMS acceptance threshold, the boot sequence completes normally.

Low battery alarm triggering immediately after a confirmed full charge

This happens because the EMP4's BMS uses a learned capacity model calibrated to the original OEM cell. A new replacement cell has not yet completed a BMS learn cycle, so the charge controller applies a conservative capacity estimate and trips the low-battery threshold earlier than expected. Run one full charge-discharge cycle on the device before any clinical use. After that cycle, the BMS recalibrates its capacity reference and the alarm threshold aligns correctly to actual cell state. Do not use the device in patient care settings until this conditioning cycle is complete.

Compatibility

Check your original model and part number before ordering.

Compatible brands
SCHWA
Fit Model
ECO+ EMP4
Part Number
101041

Specifications

Battery typeNi-MH
Voltage4.8V
Capacity2000mAh
Wh9.6Wh
Dimensions58.10 x 52.50 x 14.80mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.