Compatible with SCHWA

SCHWA EMP2 Replacement Battery - Replaces 104706

$29.36In stock

Why this battery

  • Fits SCHWA EMP2 and EMP4 Pro medical devices; replaces OEM part 104706.
  • Supplies 9.6V at 1000mAh capacity; adequate for full diagnostic cycles in portable clinical use.
  • Connector mates directly to the battery slot with positive and negative terminals aligned; no adapter required.
  • We charged this cell on a medical-grade analyzer; the BMS accepted the new pack on cycle one with stable voltage curve.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
9.6V1000mAhNi-MH

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$29.36Quantity 1

About this replacement

SCHWA EMP2 / EMP4 Pro — 9.6V Ni-MH Replacement Battery (104706)

This is the 9.6V, 1000mAh Ni-MH replacement battery for the SCHWA EMP2 and EMP4 Pro portable medical devices. It carries OEM part number 104706 and fits the original battery bay without modification. Capacity figures are taken from product data: 1000mAh at 9.6V, giving 9.6Wh.

  • EMP2 and EMP4 Pro compatibility: Both units run off the same 9.6V cell pack and share the 104706 part number. The voltage rail and connector format are identical across the two models, so one cell services either device.
  • Bench tested on actual hardware: We cycled this cell through the EMP2 charge sequence and monitored the BMS handshake. The protection circuit flagged correctly at low-voltage cutoff and accepted a full charge without thermal events or charge-IC rejection.
  • Post-installation self-test protocol: After fitting this battery, allow the device to complete its full power-on self-test without interruption. Medical-grade BMS firmware runs a verification sweep at startup — cutting power mid-sequence stores a false fault flag that persists through subsequent boots until a clean full reboot clears it.

Why the EMP2 alarms low battery immediately after a confirmed full charge

The EMP2 charge controller compares the incoming cell's voltage signature against thresholds calibrated for an OEM-conditioned Ni-MH cell. A new, uncycled cell has not yet stabilised its internal resistance, so the BMS reads a voltage drop under load that falls inside the low-battery alarm window. This is not a defective cell — it is a learn-cycle gap. Run one complete charge-discharge cycle before clinical use and the alarm clears. After that first cycle, the cell's voltage curve under load aligns with the BMS threshold and the alarm stops triggering.

EMP2 will not power on after the replacement battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. A cell that has been in storage for several weeks may have dropped below the EMP2's BMS recovery threshold — typically around 8.5V for a 9.6V pack — and the device refuses to boot. Connect the battery to the OEM charger and leave it for a full charge cycle before attempting to power on. If the charger does not begin charging, confirm open-circuit voltage across the pack terminals first; if it reads below 7V, a trickle pre-charge is needed before the standard charge cycle will engage.

Compatibility

Check your original model and part number before ordering.

Compatible brands
SCHWA
Fit Model
EMP2EMP4 Pro
Part Number
104706

Specifications

Battery typeNi-MH
Voltage9.6V
Capacity1000mAh
Wh9.6Wh
Dimensions45.60 x 42.20 x 21.20mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning