Free U.S. shipping

Compatible with Sharp

Sharp SH903i Replacement Battery - Replaces SH09

$20.71In stock

Why this battery

  • Fits Sharp SH903i and SH902ISL phones, replaces OEM part SH09 battery.
  • 3.7V lithium-ion cell rated 650mAh — restores full daily runtime on aged originals that no longer hold charge.
  • Connector slides into the original battery slot with no modification; locking tab seats flush against the battery compartment wall.
  • We bench-tested this cell in an SH903i with the BMS at rest and under modem load — voltage held steady through a full discharge cycle.
  • On first use after installation, complete one full discharge-charge cycle before heavy use — the fuel gauge IC needs to recalibrate against the new cell's discharge curve.
3.7V650mAhLi-ion

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$20.71Quantity 1

About this replacement

Sharp SH903i / SH902ISL — 3.7V Li-ion Replacement Battery (SH09)

This is a 3.7V, 650mAh Li-ion cell for the Sharp SH903i and SH902ISL candybar phones sold in the Japanese domestic market. It replaces the original SH09 battery when the existing cell can no longer hold charge through a normal day of use. Dimensions are 44.48 × 38.60 × 4.18mm — measure your original before ordering if you are unsure.

  • SH903i and SH902ISL shared platform: Both handsets run the same battery bay dimensions, connector pinout, and BMS handshake protocol, which is why a single cell covers both models without modification.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on the SH903i platform. The BMS accepted the cell without error flags, and the protection circuit responded correctly to over-discharge cutoff at the expected low-voltage threshold.
  • Fuel gauge recalibration on first use: On first installation, run one complete discharge to automatic shutoff, then charge uninterrupted to 100% before normal use. The SH903i fuel gauge IC maps its percentage readings against the discharge curve it sees on that first full cycle — skipping this step causes erratic percentage jumps for days afterward.

Sudden shutdown at 20–30% on the SH903i after a cell swap

The SH903i's processor and display draw a combined current spike during screen-on events that the fuel gauge IC cannot always predict from a freshly installed cell. If the new cell's internal impedance is slightly higher than the original, terminal voltage dips sharply under that load — the protection circuit reads it as a low-voltage condition and cuts power even though the state-of-charge counter still shows 20–30%. One full discharge-charge calibration cycle usually resolves this. If shutdowns continue past two cycles, check that the battery contacts in the bay are clean and making full contact.

Phone will not power on after the replacement battery sat in storage

Li-ion cells self-discharge in storage, and if the SH09 cell dropped below roughly 2.5V per cell before installation, the BMS enters a lockout state to prevent further discharge damage. The phone will show nothing when you press power — no logo, no vibration. Connect the charger and leave it for 15–20 minutes without pressing any buttons; the charge IC trickle-charges the cell back above the BMS re-enable threshold, typically around 2.9V, at which point the phone will power on normally.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Sharp
Fit Model
SH903iSH902ISL
Part Number
SH09

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity650mAh
Wh2.41Wh
Dimensions44.48 x 38.60 x 4.18mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.