Siemens SC7000 Patient monitor Replacement Battery - Replaces EE090263

$31.21In stock

Why this battery

  • Fits Siemens SC7000 and SC9000 patient monitors, replacing OEM part EE090263.
  • 6V 2500mAh Ni-MH chemistry sustains continuous ECG and vital-sign monitoring during portable transport and bedside observation.
  • Connector slides into the battery slot with a single locking tab; orientation is fixed by the keyed housing.
  • We tested this cell on the SC7000 bench load profile — BMS accepted the pack after first full charge cycle with no fault codes.
  • After installation, allow the device to complete its power-on self-test cycle without interruption; medical monitors run BMS verification at startup, and interrupting this sequence triggers a false battery fault that persists until the next full reboot.
6V2500mAhNi-MH

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$31.21Quantity 1

About this replacement

Siemens SC7000 / SC9000 Patient Monitor — 6V Ni-MH Replacement Battery (EE090263)

This is a 6V 2500mAh Ni-MH replacement battery for the Siemens SC7000 and SC9000 patient monitors. It replaces OEM part EE090263 and supports continuous vital signs monitoring including ECG, heart rate, and SpO2 during patient transport and bedside use. Capacity figures are taken directly from product data — 2500mAh / 15Wh.

  • SC7000 and SC9000 shared platform: Both monitors run the same 6V battery architecture, use the same connector format, and share the same BMS handshake protocol — that is why one cell fits both units without modification.
  • Bench tested on actual hardware: We cycled this cell through the SC7000 charge circuit and confirmed the BMS accepted the new cell, completed the charge handshake without error flags, and held stable voltage under the monitor's standard sensor load.
  • Post-swap self-test protocol: After installing this battery, let the monitor complete its full power-on self-test without interruption. The SC7000 runs a BMS verification sequence at boot — cutting power during this window causes the device to log a persistent battery fault that will not clear until the next clean reboot cycle.

Why the SC7000 flags a battery fault on a cell that charged correctly

The SC7000 BMS was calibrated against the internal resistance and charge curve of a conditioned OEM Ni-MH cell. A new replacement cell has a slightly higher internal resistance before its first few full cycles, which the BMS can read as outside its expected threshold. The device flags this as a fault even though the cell is functional and fully charged. One complete charge-discharge cycle is usually enough for the BMS to update its learned values and clear the flag on subsequent boots.

SC7000 shows low battery alarm within minutes of a confirmed full charge

This is a BMS self-test threshold issue, not a cell defect. The monitor's charge IC applies a conservative acceptance window on Ni-MH cells, and a new cell's voltage response under load sits just outside that window on the first cycle. The BMS interprets the voltage dip as insufficient capacity and triggers the alarm. Run one full charge-discharge cycle outside clinical use — after that, the cell's response curve normalises and the alarm clears at the correct state of charge.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Siemens
Fit Model
SC7000 Patient monitorSC9000 Patient monitor
Part Number
EE090263

Specifications

Battery typeNi-MH
Voltage6V
Capacity2500mAh
Wh15Wh
Dimensions84.50 x 51.00 x 19.00mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning