Free U.S. shipping

Compatible with Solaris

Solaris NT2A Replacement Battery - Replaces LR18650P-1P3S

$32.45In stock

Why this battery

  • Fits Solaris NT2A medical devices and replaces OEM part number LR18650P-1P3S.
  • 11.1V lithium-ion chemistry delivers 2600mAh capacity for extended clinical operation without mid-cycle dropout.
  • Connector orientation and locking tab match OEM housing — seats flush into the device cartridge.
  • We ran full charge-discharge cycles on the bench; BMS accepted load profile without cutoff anomalies.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
11.1V2600mAhLi-ion

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$32.45Quantity 1

About this replacement

Solaris NT2A — 11.1V Li-ion Replacement Battery (LR18650P-1P3S)

This is an 11.1V, 2600mAh (28.86Wh) lithium-ion battery for the Solaris NT2A portable medical device. It replaces the OEM pack directly, matching the voltage rail and connector configuration of the original. When the factory cell degrades or fails, this pack restores the device to normal operating status.

  • NT2A platform fit: The NT2A runs an 11.1V three-cell lithium-ion architecture. This pack uses the same 1P3S cell arrangement as the OEM unit, so the BMS handshake and charge termination signals align without modification or adapter.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on the NT2A platform. The BMS accepted charge normally, cell balancing completed without fault flags, and the protection circuit tripped correctly at low-voltage cutoff.
  • Post-swap self-test protocol: After installing this battery, allow the NT2A to complete its full power-on self-test cycle without interruption. Medical device firmware runs a BMS verification pass at startup — cutting power during this sequence logs a battery fault that persists until the next clean reboot, even if the pack itself is fine.

NT2A not completing boot sequence after battery swap

The NT2A firmware runs a multi-stage initialisation check that includes a BMS handshake before the device reaches its ready state. A new cell at partial state of charge may present a voltage slightly outside the firmware's expected startup window, causing the boot sequence to stall or loop. Charge the replacement pack fully before the first installation. If the device still stalls at boot, remove the battery, wait 30 seconds, reinsert, and allow the full sequence to complete — the BMS re-initialises on each insertion.

Charge indicator not reaching 100% on first charge

On the first charge cycle, the NT2A charge IC applies a conservative current limit to an unfamiliar cell, which can leave the indicator sitting at 95–98% even after the charger has been connected for several hours. This is the charge controller applying a trickle-top algorithm while it profiles the new pack — it is not a faulty cell. Run one complete charge-discharge cycle and the charge IC recalibrates its endpoint. After that cycle, the indicator should reach 100% and terminate normally.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Solaris
Fit Model
NT2A
Part Number
LR18650P-1P3S

Specifications

Battery typeLi-ion
Voltage11.1V
Capacity2600mAh
Wh28.86Wh
Dimensions66.55 x 55.20 x 20.50mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.