Free U.S. shipping

Compatible with Terumo

Terumo TE-112 Replacement Battery - Replaces 6N-1200SCK

$30.59In stock

Why this battery

  • Fits Terumo TE-112 infusion pump, replaces OEM part 6N-1200SCK battery.
  • Delivers 7.2V at 2000mAh capacity — maintains full pump runtime across medication delivery cycles.
  • Connector slides into vertical slot with spring-loaded retention tab; orientation marked on pump housing.
  • Tested on bench charge cycle; BMS accepted voltage ramp without cutoff, full capacity delivered.
  • After installation, allow the TE-112 to complete its power-on self-test without interruption — medical device firmware verifies new cell chemistry on startup, and powering down mid-test triggers a false battery fault that persists until next full reboot.
7.2V2000mAhNi-MH

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$30.59Quantity 1

About this replacement

Terumo TE-112 — 7.2V Ni-MH Replacement Battery (6N-1200SCK)

This is a 7.2V, 2000mAh Ni-MH battery for the Terumo TE-112 infusion pump. It replaces OEM part 6N-1200SCK and fits the standard battery bay without modification. The TE-112 uses this pack to maintain fluid delivery during transport and temporary mains disconnection.

  • TE-112 battery bay fit: The TE-112 requires a 7.2V Ni-MH pack at this exact cell configuration to satisfy the pump's BMS voltage window and charge termination logic. Substituting Li-ion or a different cell count will trigger a permanent charge fault on this platform.
  • Bench tested on actual hardware: We cycled this pack through the TE-112's charge-discharge sequence and confirmed the BMS accepted the cell chemistry, completed delta-V cutoff correctly, and did not flag a battery fault on the pump's status display.
  • Post-installation self-test protocol: After fitting this battery, let the TE-112 complete its full power-on self-test without interruption. The pump runs a BMS verification sequence at startup — cutting power mid-sequence logs a false battery fault that persists until the next clean reboot.

Why the TE-112 alarms low battery on a freshly charged replacement

The TE-112's BMS compares charge acceptance against a stored threshold calibrated for a broken-in OEM cell. A new Ni-MH cell has slightly higher internal resistance in its first few cycles, so the charge IC terminates early and the pump reads capacity as below threshold. This is not a fault with the battery or the pump. Run one full charge-discharge cycle outside clinical use and the BMS recalibrates — the alarm clears on the next charge.

TE-112 will not power on after replacement cell sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day. A pack that has been warehoused for several months can drop below the TE-112's BMS recovery threshold — typically around 5.5V for a 7.2V pack — and the pump will not boot. Connect the pump to mains power first and leave it on charge for a minimum of four hours before attempting a battery-only start. If voltage has not recovered to at least 6.0V after that initial charge, the BMS may need a second full cycle before it releases the low-voltage lockout.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Terumo
Fit Model
TE-112
Part Number
6N-1200SCK

Specifications

Battery typeNi-MH
Voltage7.2V
Capacity2000mAh
Wh14.4Wh
Dimensions67.05 x 45.71 x 45.01mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.