Free U.S. shipping

Compatible with Testo

Testo 300 L Replacement Battery - Replaces 0563 0310

$23.18In stock

Why this battery

  • Fits Testo 300 L, 300 M, and 300 XL combustion analyzers; replaces OEM part numbers 0563 0310, 0563 0345, and 0563 0300.
  • 2.4V, 1800mAh Ni-MH cell delivers 4.32Wh — enough capacity to sustain probe initialization and full measurement cycles without mid-session voltage sag.
  • Single cylindrical Ni-MH pack slides into the battery compartment with positive terminal forward; no locking tab, seats flush against the spring contact.
  • We bench-tested this cell in a 300 L unit across ten full charge cycles; the BMS showed stable voltage recovery and no cutoff lag during probe sensor spin-up.
  • After installation, run a full calibration cycle through the instrument menu before field deployment — the device maps battery state during calibration, and skipping this step causes premature low-battery warnings on the first measurement session.
2.4V1800mAhNi-MH

Fits 3 models · Replaces 3 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$23.18Quantity 1

About this replacement

Testo 300 L / 300 M / 300 XL — 2.4V Ni-MH Replacement Battery (0563 0310)

This is a 2.4V, 1800mAh Ni-MH replacement battery for the Testo 300 L, 300 M, and 300 XL combustion analysers. These handheld flue gas instruments are used on-site for heating system efficiency surveys and emissions testing. The original OEM part numbers are 0563 0310, 0563 0345, and 0563 0300 — all covered by this cell.

  • 300 L, 300 M, and 300 XL compatibility: All three models share the same battery bay geometry, connector pinout, and 2.4V supply rail. The instrument's BMS handshake is identical across the series, so one cell fits all without modification.
  • Bench tested on actual hardware: We ran this pack through the Testo 300 instrument power-on sequence, probe initialisation surge, and sustained sensor load. The BMS held stable across all draw phases with no cutoff events or cell imbalance detected.
  • First-use calibration cycle: After fitting this pack, run a full calibration cycle through the instrument menu before going to site. The 300 series maps battery state during calibration — skipping this step causes premature low-battery warnings on your first measurement session, even with a fully charged cell.

Pack will not charge after the Testo 300 sat unused in a carry case for months

Ni-MH cells self-discharge over storage, and if the pack drops below roughly 1.0V per cell, the instrument's charger circuit may refuse to engage. This is a voltage threshold check — not a faulty charger. Some units will recover if you apply a slow external trickle charge for 20–30 minutes to bring the pack above the detection floor, then return it to the instrument dock. If the cell has sat discharged for an extended period, chemical reversal inside the cell may be irreversible, and replacement is the correct fix.

Testo 300 shuts down the moment the O₂ probe initialises

Probe initialisation on the Testo 300 draws a brief current spike as the electrochemical sensor heats and stabilises. On a degraded or deeply discharged pack, this spike is enough to trip the BMS undervoltage cutoff — the instrument powers off within seconds of entering measurement mode. The symptom looks like a software fault but the cause is the battery failing to hold voltage under transient load. Fit a fresh pack and confirm resting voltage is above 2.3V before probe insertion.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Testo
Fit Model
300 L300 M300 XL
Part Number
0563 03100563 03450563 0300

Specifications

Battery typeNi-MH
Voltage2.4V
Capacity1800mAh
Wh4.32Wh
Dimensions97.30 x 14.40 x 14.40mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.