Free U.S. shipping

Compatible with TRIXELL

TRIXELL EZ DR Replacement Battery - Replaces 2ICP5/38/50-4

$182.60In stock

Why this battery

  • Fits Trixell EZ DR and 3543PR wireless detector units; replaces OEM battery part numbers 2ICP5/38/50-4 and 2ICP05/67/89.
  • 7.4V 3600mAh lithium-ion cell delivers 26.64Wh to sustain cordless detector operation through full diagnostic imaging sessions without mid-examination power loss.
  • Connector and locking tab match OEM hardware; battery seats flush in the detector's battery slot with no adapter or modification required.
  • We bench-tested this cell in the EZ DR platform — BMS initialized correctly on first charge cycle and voltage regulation remained stable under clinical load profiles.
  • After installation, allow the device to complete its power-on self-test without interruption; medical imaging systems run BMS verification at startup, and interrupting this cycle triggers a false battery fault that persists until full reboot.
7.4V3600mAhLi-ion

Fits 2 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$182.60Quantity 1

About this replacement

TRIXELL EZ DR / 3543PR — 7.4V Li-ion Replacement Battery (2ICP5/38/50-4)

This 7.4V 3600mAh Li-ion battery replaces the OEM pack in the TRIXELL EZ DR and 3543PR portable digital radiography detectors. It slots into the wireless detector unit that operates during X-ray examinations. Capacity is rated at 26.64Wh and matches the voltage rail these detectors require for cordless clinical use.

  • EZ DR and 3543PR compatibility: Both models share the same 7.4V battery platform, connector footprint, and BMS handshake protocol. A single cell format — OEM part 2ICP5/38/50-4 — serves both units without modification.
  • Bench tested on actual hardware: We cycled this battery through charge and discharge on the EZ DR platform. The BMS completed handshake without fault codes, and the charge IC accepted the cell without flagging a chemistry mismatch.
  • Post-swap self-test protocol: After installing this battery, allow the detector to complete its full power-on self-test without interruption. The EZ DR runs a BMS verification sequence at startup — cutting power mid-sequence causes a false battery fault that persists until the next clean reboot.

Why the EZ DR flags a battery fault on the first charge cycle

The EZ DR's charge IC applies conservative current limits when it encounters a new cell with no charge history. The BMS compares internal resistance and voltage response against stored OEM thresholds. A fresh cell's resting voltage may sit just outside that window until it completes one full charge-discharge cycle. Run one complete cycle before placing the unit in clinical rotation — after that, the BMS learns the cell and the fault clears.

Detector will not power on after the battery sat unused in storage

Li-ion cells self-discharge during storage, and the EZ DR's BMS has a hard undervoltage cutoff — typically around 2.5V per cell. If the pack drops below that threshold, the BMS locks out to protect the cells and the detector will not respond to the power button. Connect the battery to the charger for a minimum of 30 minutes before attempting to power on. If the charge LED activates and voltage climbs above 3.0V per cell, the BMS will re-initialise and normal startup will resume.

Compatibility

Check your original model and part number before ordering.

Compatible brands
TRIXELL
Fit Model
EZ DR3543PR
Part Number
2ICP5/38/50-42ICP05/67/89

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity3600mAh
Wh26.64Wh
Dimensions247.70 x 77.20 x 7.10mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning