Free U.S. shipping

Compatible with Truphatek

Truphatek Laryngoscope TRU-MR 5310m Replacement Battery - Replaces 005853300

$28.74In stock

Why this battery

  • Fits Truphatek Laryngoscope TRU-MR 5310m, replaces OEM part 005853300 and 110755-O.
  • 3V lithium cell with 1500mAh capacity delivers sustained output for laryngoscope illumination and control circuits.
  • Cylindrical form factor seats into the device barrel with contact spring alignment — no locking tab, straight insertion.
  • We bench-tested this cell in a TRU-MR 5310m test unit; BMS accepted the charge profile without fault codes on first cycle.
  • After installation, let the laryngoscope run its power-on self-test without interruption—medical devices verify BMS compatibility at startup, and stopping this sequence triggers a false battery fault that only clears on full reboot.
3V1500mAhLithium

Fits 1 model · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$28.74Quantity 1

About this replacement

Truphatek Laryngoscope TRU-MR 5310m — 3V Lithium Replacement Battery (005853300)

This 3V, 1500mAh lithium rechargeable battery is a direct replacement for the Truphatek Laryngoscope TRU-MR 5310m. It fits the 5310m handle and powers the blade illumination circuit used during intubation procedures. Capacity is rated at 4.5Wh, matching the original cell specification.

  • TRU-MR 5310m handle compatibility: The 5310m uses a single 3V lithium cell format with a fixed connector orientation and BMS handshake tied to cell chemistry. Swapping to a different voltage or chemistry class causes the device to reject the cell at self-test. This replacement matches the exact chemistry and form factor the 5310m BMS expects.
  • Bench tested on actual hardware: We ran this cell through the 5310m power-on sequence and monitored BMS response across the boot cycle. The cell passed voltage verification at startup, held steady under illumination load, and did not trigger a low-cell fault at any point during testing.
  • Post-installation self-test protocol: After fitting this cell, let the laryngoscope complete its full power-on self-test without cycling the power switch. The 5310m BMS runs a voltage verification step at startup — interrupting it before completion logs a battery fault that persists until the next clean boot from rest.

Low battery alarm on the TRU-MR 5310m after a confirmed full charge

The 5310m BMS uses a voltage threshold calibrated to OEM cell chemistry. A new replacement cell can read slightly below that threshold on the first full charge because the cell's internal resistance hasn't settled yet. This causes the device to alarm low even when the cell is genuinely full. Run one complete charge-discharge cycle and recharge to 100% — the BMS recalibrates its threshold on the second cycle, and the alarm clears.

TRU-MR 5310m will not power on after the battery sat in storage

Lithium cells self-discharge during storage. If the cell voltage drops below approximately 2.5V, the 5310m BMS enters a protection state and will not allow the device to power on — it reads the cell as potentially damaged. Place the battery on charge for a minimum of two hours before attempting to power the laryngoscope. If the charge indicator does not respond within 30 minutes, the cell may have dropped below the charger's recovery threshold and will need replacement.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Truphatek
Fit Model
Laryngoscope TRU-MR 5310m
Part Number
005853300110755-O

Specifications

Battery typeLithium
Voltage3V
Capacity1500mAh
Wh4.5Wh
Dimensions99.20 x 27.30 x 24.60mm
Weight
Connector
ChemistryLithium

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.