Free U.S. shipping

Compatible with Unitech

Unitech HT850 Replacement Battery - Replaces 2095047

$22.56In stock

Why this battery

  • Fits Unitech HT850 and HT580 handheld scanners; replaces OEM part numbers 2095047 and 1400-202536G.
  • 3.7V 800mAh Li-ion cell delivers 2.96Wh — sufficient for a full shift of mixed barcode reads and wireless polling in retail and warehouse environments.
  • Battery slides into the scanner grip with a single locking tab on the right side; connector is a two-pin male type that seats flush against the device contact plate.
  • We bench-tested this pack in an HT850 dock; the BMS accepted the charge handshake on first insertion and held steady through discharge at both light and heavy scan-burst loads.
  • On first use, place the scanner in its cradle for a complete charge cycle before deploying to the floor — the scan trigger draws peak inrush current when cells are near minimum and a pre-charged pack prevents false BMS cutoff during rapid barcode bursts.
3.7V800mAhLi-ion

Fits 2 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$22.56Quantity 1

About this replacement

Unitech HT850 / HT580 — 3.7V Li-ion Replacement Battery (2095047)

This 3.7V 800mAh Li-ion battery fits the Unitech HT850 and HT580 handheld barcode scanners. Both are compact mobile data terminals used in retail, logistics, and warehouse environments for barcode capture and data entry. It matches OEM part numbers 2095047 and 1400-202536G.

  • HT850 and HT580 compatibility: Both models share the same battery bay dimensions, 3.7V power rail, and connector pinout. The BMS handshake protocol is identical across the HT850 and HT580, so one cell fits both without modification.
  • Bench tested on actual hardware: We ran this pack on the HT850 platform and confirmed the BMS accepted the cell without a fault code. Scan trigger inrush and wireless polling drew simultaneous current without tripping the protection circuit.
  • First-shift prep for pick-and-pack: After installing, place the scanner in its cradle for a full charge cycle before starting a shift. Scan trigger inrush is highest when the cell is near minimum, and a fully charged pack prevents false BMS trips on the first burst of scanning.

Cradle showing a charging error on a new pack

A charging error on the dock immediately after fitting a new cell usually points to contact resistance at the battery terminals, not a faulty pack. Debris or oxidation on the gold-plated contacts breaks the low-voltage handshake the cradle uses to verify cell chemistry before starting the charge cycle. Wipe the battery contacts and the cradle's spring pins with a dry cloth, then reseat the scanner firmly until you hear the click. The error clears once contact resistance drops below the dock's threshold and the handshake completes.

Scanner losing wireless connection during a rapid scan burst

When the imager fires and the wireless radio transmits simultaneously, peak current draw spikes sharply in a short window. On a degraded or deeply discharged cell, this combined inrush pulls the cell voltage below the BMS cutoff, which briefly kills the radio stack before the cell recovers. The result looks like a dropped connection rather than a power fault, so it is easy to misdiagnose as a Wi-Fi issue. Charge the pack to full — at least 4.1V open-circuit — before the shift so the cell has enough headroom to handle both loads at once.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Unitech
Fit Model
HT850HT580
Part Number
20950471400-202536G

Specifications

Battery typeLi-ion
Voltage3.7V
Capacity800mAh
Wh2.96Wh
Dimensions44.00 x 34.00 x 5.20mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.