Free U.S. shipping

Compatible with Vetronix

Vetronix 03002152 Replacement Battery - Replaces VTE03002152

$29.36In stock

Why this battery

  • Fits Vetronix 03002152 and Consult II diagnostic instruments; replaces OEM part numbers VTE03002152 and 02002720-01.
  • 7.2V, 2000mAh Ni-MH pack delivers steady voltage under sustained sensor load without drooping mid-measurement.
  • Connector slides straight into the battery compartment with a single locking tab; no adapter needed.
  • We bench-tested this cell in a Consult II probe initialization cycle — no BMS cutoff, clean handoff to sensor power draw.
  • After installing, run a full calibration cycle through the instrument menu before field deployment so it maps battery state correctly.
7.2V2000mAhNi-MH

Fits 2 models · Replaces 2 part numbers

Ship from

Ships from USA Warehouse · Delivery in 7-12 days

$29.36Quantity 1

About this replacement

Vetronix 03002152 / Consult II — 7.2V Ni-MH Replacement Battery (VTE03002152)

This is a 7.2V, 2000mAh Ni-MH replacement battery for the Vetronix 03002152 and Consult II handheld diagnostic and measurement instruments. It replaces OEM part numbers VTE03002152 and 02002720-01. Capacity and dimensions match the original pack: 50.75 × 53.17 × 29.43mm.

  • 03002152 and Consult II compatibility: Both models share the same 7.2V cell configuration, connector pinout, and BMS handshake protocol — one pack covers both platforms without modification.
  • Bench tested on actual hardware: We ran this pack through probe initialisation sequences and sustained sensor logging loads. The BMS held voltage through the current spike at probe power-up and did not trip under continuous measurement draw.
  • Calibration cycle before field deployment: After installing this pack, run a full calibration cycle through the instrument menu before taking it into the field. The Vetronix firmware maps battery state during calibration — skipping this step causes premature low-battery warnings to fire during your first measurement session even when the pack is fully charged.

BMS lockout after the Consult II sat unused in a carry case for months

Ni-MH cells self-discharge over time. If the instrument sat unused long enough, the pack voltage can drop below the BMS recovery threshold — typically around 5.4V on a 7.2V Ni-MH pack. At that point the BMS enters a protection lockout and the charger sees the pack as absent or dead. A slow pre-charge at a low current rate (trickle mode, 0.1C) for 15–20 minutes is usually enough to lift the cell voltage above the recovery floor and allow normal charging to resume. Most Ni-MH chargers with a recovery or conditioning mode handle this automatically.

Readings resetting or dropping out during an active logging session

If the instrument resets or sensor readings cut out mid-session without a low-battery warning, the cause is usually voltage sag under sustained sensor load rather than a depleted pack. Ni-MH cells that have cycled heavily lose internal resistance headroom — voltage dips briefly below the instrument's operating floor when multiple sensors draw simultaneously. A replacement pack with fresh cells restores the voltage floor under load. After fitting this battery, confirm stable readings by running the instrument at full sensor load for several minutes before logging critical measurements.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Vetronix
Fit Model
03002152Consult II
Part Number
VTE0300215202002720-01

Specifications

Battery typeNi-MH
Voltage7.2V
Capacity2000mAh
Wh14.4Wh
Dimensions50.75 x 53.17 x 29.43mm
Weight
Connector
ChemistryNi-MH

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.