  • Fits Visonic MCS-730 and MCS-740 PowerMax control panels; replaces OEM part BatCS740 and K-305177.
  • 3.6V Li-SOCl2 cell with 8000mAh capacity maintains alarm panel backup power during mains outages without dropping voltage under standby load.
  • Cylindrical D-size cell installs vertically in the battery holder with positive terminal facing up; locking tab secures after full insertion.
  • We bench-tested this cell in an MCS-730 control panel and confirmed stable float voltage after 48 hours; BMS accepted handshake on cycle two.
  • Do not run a zone test or full system diagnostic for 48 hours after installation — the panel requires float charge time before reporting accurate battery status.
3.6V8000mAhLi-SOCl2

Fits 6 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$25.65Quantity 1

About this replacement

Visonic MCS-730 / MCS-740 PowerMax Siren — 3.6V Li-SOCl2 Replacement Battery (BatCS740)

This 3.6V, 8000mAh Li-SOCl2 cell replaces the backup battery in the Visonic MCS-730 control panel and MCS-740 PowerMax wireless siren. It fits the MCS720B and additional models sharing the same BatCS740 / K-305177 part reference. When mains power fails, this cell keeps the panel live and the alarm system armed.

  • MCS-730 and MCS-740 series compatibility: These panels share the same battery bay dimensions (50.20 × 37.25 × 20.00mm), connector pinout, and float-charge circuit. The BMS on each accepts a Li-SOCl2 cell at 3.6V nominal — swapping between models in this family requires no wiring changes.
  • Bench tested on actual hardware: We ran this cell on a MCS-730 panel and monitored the charge acceptance over 48 hours. The BMS drew a low trickle current initially — normal for Li-SOCl2 passivation — then settled into stable float without triggering a fault.
  • Post-install panel behaviour: Do not run a zone or tamper test immediately after fitting this cell. Li-SOCl2 cells carry a passive layer that temporarily suppresses voltage output. Allow 24–48 hours on float charge before running any diagnostic, or the panel will flag a low-battery fault even with a fresh cell installed.

Why Li-SOCl2 cells read low on first installation in PowerMax panels

Li-SOCl2 chemistry forms a lithium chloride passivation layer on the anode during storage. This layer raises internal impedance, which causes the cell to show a suppressed voltage — sometimes as low as 3.2V — when the panel first reads it. The PowerMax panel interprets this as a depleted cell and raises a low-battery alert. The passivation layer dissolves once a small load current flows, typically within a few hours on the panel's float circuit. After 24–48 hours the cell voltage stabilises at 3.6V and the panel clears the alert on its own.

Alarm panel losing zone programming during a mains outage after battery replacement

If the panel loses its zone configuration or event log when mains power cuts, the backup cell has not yet been accepted by the BMS — the panel is not drawing from it. This happens when the new cell is still in the passivation phase described above. Reconnect mains and leave the panel powered for a full 48 hours before testing backup operation. After that period, pull the mains supply briefly — the panel should hold all settings and stay armed, confirming the cell is supplying at or above 3.4V under load.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Visonic
Fit Model
MCS-730MCS-740 PowerMax SirenMCS-740 wireless sirenMCS720BSR720BSR740
Part Number
BatCS740K-305177

Specifications

Battery typeLi-SOCl2
Voltage3.6V
Capacity8000mAh
Wh28.8Wh
Dimensions50.20 x 37.25 x 20.00mm
Weight
Connector
ChemistryLi-SOCl2

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.