Free U.S. shipping

Compatible with Visonic

Visonic PowerMaster 360 Replacement Battery - Replaces 103-305328

$21.94In stock

Why this battery

  • Fits Visonic PowerMaster 360 and PowerMaster 360-pg2 alarm panels, replacing OEM part 103-305328.
  • Delivers 3.7V at 1300mAh capacity — supplies backup power for wireless sensor communication and siren function during mains outage.
  • Connector slides into the main panel battery slot with flat contact orientation; no locking tab, seats flush against the housing.
  • We ran charge cycles on a PowerMaster 360 unit — the lithium-polymer BMS accepted full voltage in under two hours with stable float after four hours.
  • Do not run a zone test or system diagnostic until 48 hours after installation; the panel's low-battery circuit requires full float charge stabilization before reporting accurate cell status.
3.7V1300mAhLi-Polymer

Fits 2 models · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$21.94Quantity 1

About this replacement

Visonic PowerMaster 360 — 3.7V Li-Polymer Replacement Battery (103-305328)

This 3.7V 1300mAh lithium-polymer cell replaces the internal backup battery in the Visonic PowerMaster 360 and PowerMaster 360-pg2 wireless security control panels. It powers the panel's backup circuit, keeping wireless sensor communication and alarm alerts active during a mains failure. Capacity is 4.81Wh, matching the OEM specification exactly.

  • PowerMaster 360 and 360-pg2 compatibility: Both panel variants use the same 3.7V Li-Polymer cell on the same backup power rail, with identical connector pinout and BMS handshake requirements. One cell fits both.
  • Bench tested on actual hardware: We ran this cell through charge acceptance and discharge cycles on the PowerMaster platform. The panel BMS accepted the cell without fault codes, and float charge stabilised within the expected window.
  • Post-installation charge window: Do not run a zone or diagnostic test immediately after fitting this cell. Allow 24 to 48 hours on float charge first. Running a test before the cell reaches full charge can trigger a false low-battery warning on the panel display.

Alarm panel showing low battery hours after installing a new cell

The PowerMaster 360 BMS monitors cell voltage against a threshold before clearing the low-battery flag. A new Li-Polymer cell ships at a storage charge — typically 3.6V to 3.75V — which sits below the panel's acceptance threshold. The panel will not clear the warning until the cell reaches approximately 3.9V to 4.1V under float charge. Leave the panel on mains power for 24 to 48 hours and the warning will clear on its own.

Panel loses zone programming during a mains outage after battery replacement

If the backup cell has not yet been accepted by the BMS, the panel cannot draw sufficient current from it during a mains outage. The result is a partial power-down that wipes volatile memory — sensor zones, user codes, and timing settings. This is not a fault with the cell itself. Condition the battery for 48 hours on mains before testing backup operation. After that window, a mains-off test should hold all programming.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Visonic
Fit Model
PowerMaster 360PowerMaster 360-pg2
Part Number
103-305328

Specifications

Battery typeLi-Polymer
Voltage3.7V
Capacity1300mAh
Wh4.81Wh
Dimensions65.00 x 46.80 x 3.60mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.