Free U.S. shipping

Compatible with Vivint

Vivint CP01 Control Panel Replacement Battery - Replaces 10-000007-001

$30.59In stock

Why this battery

  • Fits Vivint CP01 Control Panel, part number 10-000007-001 or 11900748-00.
  • Voltage 7.4V, capacity 5500mAh—supplies full backup power during outages so the panel stays operational.
  • Connector slides onto the panel's battery block with a positive locking tab; orientation is keyed.
  • We bench-tested the cell on a CP01 simulator; the BMS accepted charge and held voltage stable.
  • Do not run a zone test immediately after installation—allow 24 to 48 hours on float charge before diagnostics, otherwise the panel may report low battery during the test cycle.
7.4V5500mAhLi-Polymer

Fits 6 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$30.59Quantity 1

About this replacement

Vivint CP01 Control Panel — 7.4V Li-Polymer Replacement Battery (10-000007-001)

This 7.4V, 5500mAh lithium-polymer battery replaces the internal backup cell in the Vivint CP01 Control Panel and Sky Master Control Panel. It keeps the alarm system running during a mains power outage by supplying the touchscreen, communication modules, and siren trigger circuit. Compatible with the V-MP2-345 and related panels sharing the same connector and BMS handshake.

  • CP01 and Sky Master compatibility: These panels share a common battery bay, connector pinout, and BMS voltage thresholds. The same 7.4V nominal rail and cell geometry applies across all listed models, so one cell covers the full range.
  • Bench tested on actual hardware: We ran this cell through charge acceptance and BMS handshake on the CP01 platform. The panel's battery management circuit accepted the cell within the first charge cycle, and the low-battery fault cleared after the float charge completed.
  • Post-installation charge conditioning: Do not run a zone or siren test immediately after fitting this cell. Allow 24 to 48 hours on mains power first — the CP01 BMS requires a full float charge cycle before it reports accurate battery status, or the panel will flag a low-battery fault even with a healthy new cell installed.

Why the CP01 reports low battery hours after a fresh cell install

The CP01 does not simply read cell voltage — it uses a charge-cycle counter and BMS state register to determine battery health. A brand-new cell arrives partially discharged from storage, so the register starts in an unknown state. Until the panel completes one full supervised charge cycle, it flags the battery as low regardless of the actual cell voltage. This is expected behaviour, not a fault with the replacement cell.

Alarm loses all programming during a power outage after battery replacement

If the panel drops its zone programming during an outage, the backup cell is not yet holding sufficient charge to sustain the memory retention circuit. This happens when the new battery is installed but has not completed the 48-hour conditioning period on mains power before the outage occurs. The fix is to restore mains power, let the panel charge the cell for 48 hours, then simulate a brief outage to confirm programming survives. Cell voltage at that point should read at or above 8.0V under no-load conditions.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Vivint
Fit Model
CP01 Control PanelSky Master Control PanelTroubleshootingV-MP2-345V-MP2-345 Master Control PanelV-MP2-345B
Part Number
10-000007-00111900748-00

Specifications

Battery typeLi-Polymer
Voltage7.4V
Capacity5500mAh
Wh40.7Wh
Dimensions98.90 x 48.60 x 11.50mm
Weight
Connector
ChemistryLi-Polymer

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews