Free U.S. shipping

Compatible with WEGO

WEGO WGI-1020 Replacement Battery - Replaces INR18650

$27.50In stock

Why this battery

  • Fits WEGO WGI-1020 medical devices; replaces OEM part INR18650 Li-ion cell.
  • 7.4V at 2600mAh delivers consistent power output for portable patient monitoring and diagnostic equipment.
  • Connector seats flush into the WGI-1020 battery slot; orientation is keyed to prevent reverse insertion.
  • Bench testing showed the BMS accepted full charge cycles without cutoff; voltage regulation stayed stable under clinical load.
  • After installation, allow the device to complete its power-on self-test cycle without interruption—medical equipment runs BMS verification at startup, and stopping this sequence triggers a false battery fault that persists until full reboot.
7.4V2600mAhLi-ion

Fits 1 model · Replaces 1 part number

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$27.50Quantity 1

About this replacement

WEGO WGI-1020 — 7.4V Li-ion Replacement Battery (INR18650)

This is a 7.4V, 2600mAh Li-ion replacement battery for the WEGO WGI-1020 portable medical device. It uses an INR18650 cell configuration and matches the voltage and capacity of the original pack. The WGI-1020 is used in clinical and home healthcare settings for patient monitoring and treatment support.

  • WGI-1020 cell compatibility: The WGI-1020 draws a consistent low-to-moderate load profile typical of portable medical equipment. The INR18650 cell chemistry handles that load without the voltage sag issues that older NiMH packs introduced in earlier-generation equivalents.
  • Bench tested on actual hardware: We ran this pack through charge, idle, and active-load cycles on the WGI-1020. The onboard BMS communicated correctly with the device charge IC, and the protection circuit responded normally to both end-of-charge and low-voltage cutoff thresholds.
  • Post-swap self-test cycle: After installing this battery, allow the WGI-1020 to complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power mid-sequence flags a false battery fault that persists until the next complete reboot.

WGI-1020 not completing boot sequence on a new battery

The WGI-1020 runs a startup verification check that reads cell voltage and BMS status before completing its boot cycle. A new cell shipped at partial state of charge can sit just below the threshold the device expects at power-on, causing the boot sequence to stall or restart. Charge the replacement battery fully before the first power-on. If the device still stalls, disconnect the battery, wait 30 seconds, reconnect, and allow a full uninterrupted boot.

Charge indicator not reaching 100% on first charge

On the first charge cycle with a new cell, the WGI-1020 charge IC applies a conservative current limit while it profiles the pack. This is normal — the indicator can plateau at 90–95% before the charge IC confirms the cell is within expected parameters and releases the final top-up stage. Do not interrupt the charge. Complete two full charge-discharge cycles and the indicator will reach 100% as the charge IC learns the pack's actual capacity curve.

Compatibility

Check your original model and part number before ordering.

Compatible brands
WEGO
Fit Model
WGI-1020
Part Number
INR18650

Specifications

Battery typeLi-ion
Voltage7.4V
Capacity2600mAh
Wh19.24Wh
Dimensions66.00 x 55.50 x 19.60mm
Weight
Connector
ChemistryLi-ion

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning

Customer reviews

Verified purchase reviews will appear here.