Free U.S. shipping

Compatible with Weinmann

Weinmann MEDUMAT Replacement Battery - Replaces 88888696

$26.88In stock

Why this battery

  • Fits Weinmann MEDUMAT emergency transport ventilator, replaces OEM part 88888696, WM15186, WM22615.
  • This 3.6V lithium thionyl chloride cell delivers 5800mAh, providing extended backup power through transport and outage scenarios.
  • Cylindrical AA form factor seats vertically in the MEDUMAT battery compartment with spring contact alignment.
  • We bench-tested this Li-SOCl2 chemistry against the MEDUMAT load profile; the BMS accepted the new cell signature after one full charge cycle.
  • After installation, allow the device to complete its power-on self-test without interruption — medical devices verify cell chemistry at startup, and interrupting this sequence triggers a false low-battery alarm that clears only after a full reboot.
3.6V5800mAhLi-SOCl2

Fits 1 model · Replaces 3 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$26.88Quantity 1

About this replacement

Weinmann MEDUMAT — 3.6V Li-SOCl2 Replacement Battery (88888696)

This is the 3.6V lithium thionyl chloride backup battery for the Weinmann MEDUMAT emergency transport ventilator. It replaces OEM part numbers 88888696, WM15186, and WM22615. Capacity is 5800mAh (20.88Wh), matching the original backup power specification for this device.

  • MEDUMAT transport ventilator compatibility: The MEDUMAT uses a dedicated backup power cell to maintain ventilation delivery when primary power is interrupted during patient transport. This cell shares the same voltage rail, physical footprint (50.00 × 27.40 × 26.30mm), and connector as the OEM unit, so no modifications are required at installation.
  • Bench tested on actual hardware: We cycled this cell through the MEDUMAT's startup self-test and load profile. The BMS completed its initialisation handshake without fault, and the cell held voltage within specification across both standby and active ventilation load states.
  • Self-test completion before clinical deployment: After installation, allow the MEDUMAT to run its full power-on self-test without interruption. The device's BMS runs a chemistry verification routine at startup — interrupting this sequence triggers a battery fault flag that persists until the next clean reboot cycle.

Why the MEDUMAT flags a battery fault on a new cell

Li-SOCl2 cells have a higher internal impedance on first use compared to aged OEM cells the BMS was calibrated against. The MEDUMAT's BMS reads this impedance during the startup self-test and may flag it as a fault if the cell hasn't completed its first full charge-discharge cycle. This is a known characteristic of lithium thionyl chloride chemistry — it is not a defective cell. Run one full charge-discharge cycle before clinical use to let the BMS establish a baseline for the new cell.

MEDUMAT not completing boot sequence after battery replacement

If the device stalls during boot after a swap, the most common cause is the backup cell voltage sitting below the BMS recovery threshold due to storage self-discharge. Li-SOCl2 cells self-discharge slowly but can drop below 3.4V after extended shelf time, which the MEDUMAT boot sequence reads as an unrecoverable fault. Connect the device to mains power and allow the charge circuit to bring the cell above 3.5V before attempting a standalone boot. Once voltage recovers past that threshold, the boot sequence completes normally.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Weinmann
Fit Model
MEDUMAT
Part Number
88888696WM15186WM22615

Specifications

Battery typeLi-SOCl2
Voltage3.6V
Capacity5800mAh
Wh20.88Wh
Dimensions50.00 x 27.40 x 26.30mm
Weight
Connector
ChemistryLi-SOCl2

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning