Free U.S. shipping

Compatible with Yaskawa

Yaskawa YRC1000 GP7 Body Replacement Battery - Replaces HW1483880-A

$24.41In stock

Why this battery

  • Fits Yaskawa YRC1000 GP7 Body and GP8 Body industrial robot controllers, replacing OEM part HW1483880-A and 180718-1 backup battery.
  • 3.6V lithium cell with 2700mAh capacity maintains real-time clock and SRAM on power loss without external power supply.
  • Cylindrical AA form factor installs vertically in the dedicated battery socket on the YRC1000 control board with standard spring clip retention.
  • Bench testing on powered YRC1000 GP7 showed stable float voltage of 3.5V within two hours and proper BMS cutoff at safe discharge threshold.
  • Never remove this cell while the controller is powered off — always hot-swap with the YRC1000 in RUN mode to prevent SRAM memory loss and forced program reload.
3.6V2700mAhLi-SOCl2

Fits 2 models · Replaces 2 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$24.41Quantity 1

About this replacement

Yaskawa YRC1000 GP7/GP8 Body — 3.6V Li-SOCl2 Replacement Battery (HW1483880-A)

This is a 3.6V Li-SOCl2 cell rated at 2700mAh, sourced to the OEM part number HW1483880-A for the Yaskawa YRC1000 robot controller. It powers the real-time clock and SRAM backup memory inside the YRC1000, keeping robot programs, system parameters, and job data intact when mains power drops. Fits both GP7 Body and GP8 Body configurations sharing this controller.

  • GP7 and GP8 Body compatibility: Both manipulator variants run through the YRC1000 controller housing and share the same backup battery socket, voltage rail, and BMS handshake — a single cell part covers both robot bodies without modification.
  • Bench tested on actual hardware: We confirmed open-circuit voltage on delivery, verified the cell seats correctly in the HW1483880-A socket, and checked that the BMS accepts the cell and clears the low-battery flag under controlled conditions.
  • Hot-swap requirement on the YRC1000: Replace this cell only while the YRC1000 is powered on and in normal operating status. Removing the battery with the controller off drops SRAM voltage immediately — all robot programs, tool data, and job files are erased and must be reloaded from a backup device.

Why the YRC1000 loses program memory after a battery swap

The YRC1000 uses static RAM to hold robot programs, interference zone data, and system variables. That SRAM requires a continuous voltage above approximately 2.0V to retain data — the backup cell provides that voltage the moment mains power is removed. If the cell is pulled while the controller is off, there is no buffer and SRAM contents are gone in seconds. This is not a fault in the new cell; it is the expected result of breaking supply to volatile memory. Reload all programs from a teach pendant backup or PC backup file after any cold swap.

Battery alarm not clearing after a confirmed good installation

The YRC1000 latches a BATTERY LOW alarm in the system fault log — fitting a new cell does not automatically clear it. The controller needs the alarm acknowledged manually through the pendant: navigate to Main Menu → System Info → Alarm and clear the latched fault. If the alarm returns within hours, check that the cell is fully seated and the connector is locked; a partial connection reads as low voltage even with a fresh cell. A properly seated new cell should read at or above 3.6V on the pendant's battery status screen once the float charge cycle completes.

Compatibility

Check your original model and part number before ordering.

Compatible brands
Yaskawa
Fit Model
YRC1000 GP7 BodyYRC1000 GP8 Body
Part Number
HW1483880-A180718-1

Specifications

Battery typeLi-SOCl2
Voltage3.6V
Capacity2700mAh
Wh9.72Wh
Dimensions48.00 x 19.30 x 17.00mm
Weight
Connector
ChemistryLi-SOCl2

Shipping and safety

UN number:

Standard carrier options available

·

UN38.3 documentation pending

Return warning