ZOLL 8000-0299-01 Replacement Battery - Replaces 8000-0299-01

$241.92In stock

Why this battery

  • Fits ZOLL AED Pro Defibrillator and replaces OEM part numbers PD4410, 8000-0299-01, B11099, 8000-0299-10, 110087.
  • This 10V 2500mAh sealed lead acid cell powers the full defibrillation charge cycle and CPR guidance audio in the AED Pro.
  • Connector slides into the battery slot with a single locking tab; orientation is marked on the housing and is not reversible.
  • We bench tested this pack on a PD 1400 test unit; the charger accepted the cell without fault codes and reached full capacity.
  • After installation, allow the device to complete its power-on self-test cycle without interruption — the AED Pro runs BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
10V2500mAhSealed Lead Acid

Fits 17 models · Replaces 5 part numbers

Ship from

Ships from Hong Kong Warehouse · Delivery in 28-45 days

$241.92Quantity 1

About this replacement

ZOLL AED Pro Defibrillator — 10V Sealed Lead Acid Replacement Battery (PD4410)

This is a 10V 2500mAh sealed lead acid replacement battery for the ZOLL AED Pro Defibrillator and compatible ZOLL PD series devices. It replaces OEM part numbers PD4410, 8000-0299-01, B11099, 8000-0299-10, and 110087. The battery powers defibrillation delivery and CPR guidance functions during cardiac emergencies.

  • AED Pro and PD series compatibility: The AED Pro, PD 1400, PD 1600, and PD 1700 share the same 10V sealed lead acid architecture and connector interface. The BMS in each device reads cell voltage and internal resistance at boot — this battery meets those thresholds across the platform.
  • Bench tested on actual hardware: We ran this cell through charge, standby, and simulated load cycles. The BMS accepted the battery without fault codes, and charge acceptance was consistent across the full 25Wh capacity.
  • Post-installation self-test protocol: After fitting this battery, let the device complete its full power-on self-test without interruption. The AED Pro runs BMS verification at startup — cutting power mid-sequence registers a false battery fault that persists until the next clean reboot.

Self-test failure after battery swap on the AED Pro

The AED Pro runs an automated self-test at startup that checks battery voltage, charge state, and internal resistance against stored OEM thresholds. A new sealed lead acid cell that has not completed a full charge-discharge cycle may sit just below the resistance threshold the device expects. This is a BMS learn cycle issue, not a defective battery. Charge the replacement fully, allow one complete discharge and recharge cycle, then re-run the self-test — the device should clear the fault and confirm ready status.

Low battery alarm triggers immediately after confirmed full charge

This happens when the device reads cell voltage during the post-charge rest period before surface charge dissipates. Sealed lead acid cells hold an elevated surface voltage immediately after charge that drops to true resting voltage within 30 to 60 minutes. The AED Pro's alarm threshold is calibrated to resting voltage, not peak charge voltage. Wait 60 minutes after charge completes, then power the device on — resting voltage on a healthy cell should read above 10.2V and the alarm will not retrigger.

Compatibility

Check your original model and part number before ordering.

Compatible brands
ZOLL
Fit Model
8000-0299-018000-0299-10AED Pro DefibrillatorDefibrillator NTP2E-SerieM SeriesM-Serie (CCT)PD 1400PD 1600PD 1700PD 2000PD 4410PD1400PD1600PD1700PD2000PD4410
Part Number
8000-0299-018000-0299-10110087B11099PD4410

Specifications

Battery typeSealed Lead Acid
Voltage10V
Capacity2500mAh
Wh25Wh
Dimensions190.00 x 71.30 x 39.00mm
Weight
Connector
ChemistrySealed Lead Acid